24
GB
Message/symptom
Possible cause
Remedial measures
Extraction power missing
3LSHV\VWHPOHDNLQJ
5HVHDOWKHSLSHV\VWHP
)LOWHULVGLUW\
FKDQJHWKH¿OWHU
Turbine speed too low
Increase the speed setting
Loud extraction noises
Air speed through extractionarm
is too high speed
Reduce the air speed (reduce air
TXDQLWLW\
Zero Smog is not running
7KHUPDOO\VZLWFKHGRII
Leave the Zero Smog to cool
down Switch on again afterap-
prox. 3 hours
)LOWHUGLVSOD\LVQRW
working
Minimum pressure hose was not
UHSODFHGDIWHUWKH¿OWHUFKDQJH
5HFRQQHFWWKHKRVHWRWKH¿OWHU
3DUWLFOH¿OWHUGHSOHWHGWRR
TXLFNO\
3UH¿OWHUKDVQRWEHHQXVHG
8VHDSUH¿OWHU)LWDQ)¿OWHU
8VHDSUHOLPLQDU\VHSHUDWRULIWKH
proportion of solid matter is high.
8QDEOHWRGHWHFW86%
medium
86%PHGLXPLQVHUWHGWRRORQJ
'RQRWOHDYH86%PHGLXP
inserted for longer than 2
PLQXWHV5HPRYH86%PHGLXP
and switch unit off and on again
Reset unit
:URQJ86%PHGLXP!P$
5HPRYH86%PHGLXP
Error messages and error clearance
Care and maintenance
Notice
'LIIHUHQWÀX[HVDQGÀX[
constituents and the amount
of and size of dust particles
LQWKHH[WUDFWHGDLUZLOOVLJQL¿
FDQWO\HIIHFWWKH¿OWHUVZRU
-
NLQJOLIH$JDV¿OWHUZLWKRXW
SDUWLFOH¿OWHUPXVWEHXVHG
for the extraction of adhesive
fumes.
7RHQVXUHWKDWWKH¿OWUDWLRQV\VWHPIXQFWLRQVSURSHUO\WKH¿OWHUPXVW
be replaced as follows
DWOHDVWRQFHD\HDURU
when indicated or
if the maximum allowable workplace concentration is exceeded or
as per maintenance schedule
7KHGHJUHHRIFORJJLQJRIWKH¿OWHULVGHWHUPLQHGE\GLIIHUHQWLDOSUHV
-
VXUHPHDVXUHPHQW7KH¿OWHUGLVSOD\LQGLFDWHVWKHFXUUHQW¿OWHUVWDWXV
5HG ¿OWHUIXOO
<HOORZ ¿OWHUVWDWXV!
*UHHQ ¿OWHUVWDWXV
:KHQWKH¿OWHULVXVHGXSDQDXGLEOHVLJQDOVRXQGV
once an hour
HYHU\KDOIKRXUDIWHUKRXUV
HYHU\PLQDIWHUKRXUV
FRQWLQXRXVO\DIWHUKRXUV
7KHSDUWLFOH¿OWHUDQGWKHJDV¿OWHUDUHFRRUGLQDWHGLQVXFKDZD\
WKDWWKH\FDQEHUHSODFHGWRJHWKHUDVDFRPSDFW¿OWHUXQLW7KHFRP
-
SDFW¿OWHUPXVWEHFKDQJHGRQFHD\HDULQRUGHUWRHQVXUHLWLVIXOO\
IXQFWLRQDO7KH¿QHGXVW¿OWHU¿OWHUPDWLVWKHSUHOLPLQDU\VWDJHRI
WKHFRPSDFW¿OWHUDQGWKHUHIRUHPXVWEHUHSODFHGPRUHIUHTXHQWO\,W
LVVXI¿FLHQWWRUHSODFHWKHSUH¿OWHUPDWLIWKHUHG/('GRHVQRWFRPH
on after restarting the unit.
Warning!
Before doing any work on
the machine, pull the plug
out of the socket.
Use original replacement
parts only.
&RQWDPLQDWHG¿OWHUVPXVWEH
treated as special waste.
Dispose of replaced equip-
PHQWSDUWV¿OWHUVRUROG
devices in accordance with
the rules and regulations
applicable in your country.
www.
GlobalTestSupply
.com
Find Quality Products Online at: