KDS808 / KDS834A / KDS824A

Weller-Logo_2011 in „Weller-Blau“

Größen-Variationen

99 Washington Street 
Melrose, MA 02176 
Phone 781-665-1400
Toll Free 1-800-517-8431

Visit us at www.TestEquipmentDepot.com

Summary of Contents for Kahnetics KDS808

Page 1: ...KDS808 KDS834A KDS824A Weller Logo_2011 in Weller Blau 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Page 2: ...KDS808 1 Pressure gauge for air outlet 2 Anti drip vacuum adjuster 3 Power switch 4 Air outlet for cartridge 5 Pressure regulator for air outlet...

Page 3: ...KDS808 6 Foot switch socket 7 Coupling for external air supply 8 0 5A fuse 9 Voltage selector switch 10 Power socket...

Page 4: ...drip vacuum adjuster 2 Time setting in sec 3 Pressure gauge for air outlet 4 Pressure regulator for air outlet 5 Air outlet for cartridge 6 MANUAL TIMER mode selector 7 Power switch 8 Indicator for di...

Page 5: ...KDS834A 9 Foot switch socket 10 Coupling for external air supply 11 0 5A fuse 12 Voltage selector switch 13 Power socket...

Page 6: ...et 3 Time setting in sec 4 Indicator for dispensing pulse 5 Anti drip vacuum adjuster 6 Pressure gauge for Accessories air outlet 7 Pressure regulator for Accessories air outlet 8 MANUAL TIMER mode se...

Page 7: ...KDS824A 12 Foot switch socket 13 Coupling for external air supply 14 0 5A fuse 15 Voltage selector switch 16 Power socket...

Page 8: ...spenser with an integral pressure regulator from 0 7 bar and pressure gauges Adjustable vacuum prevents dripping by the dispensed medium Digital timer control for repeatable dispensed quantities Dispe...

Page 9: ...it decimal push buttons 2 3 Range of adjustment 0 01 99 99 sec Set the air pressure regulator 4 1 to the desired operating pressure 10 Turn on the unit 7 11 11 Operate the foot switch With automatic t...

Page 10: ...sure regulator Use a dispensing needle with a different diameter For units with timer control change the timer setting The first dispensing pulses after a cartridge change can produce different amount...

Page 11: ...nd enclosed place out of the reach of children 6 Do not overload the device Operation is better and safer within the specified power and pressure range 7 Use the right device for the job Do not use a...

Page 12: ...centre provided that no other instructions are given in the operating instructions 18 Attention Only use accessories or auxiliary devices that are listed in the accessories list found in the operating...