B. CHARGING BATTERY INSTALLED IN VEHICLE
Note: Connect and disconnect the DC output clamps ONLY AFTER
removing the AC plug from the electrical outlet. Never allow the DC
output clamps to touch each other. This may cause a spark.
CHOOSE THE GROUND SYSTEM YOU WILL USE AND
FOLLOW THE STEPS
Connecting to a negative-grounded system:
1. Connect the positive (+) red clip from the battery charger to a
positive (POS, P, +) ungrounded post of the battery.
2. Connect the negative (-) black clip to the vehicle chassis or engine
block away from battery.
DO NOT connect clip to carburetor, fuel lines, or sheet-metal body
parts.
Connect to a heavy gauge metal part of the frame or engine block.
Connecting to a positive-grounded system:
1. Connect the negative (-) black clip from battery charger to the
Negative (NEG, N, -) ungrounded post of battery.
2. Connect the positive (-) red clip to the vehicle chassis or engine
block away from battery.
DO NOT connect clip to carburetor, fuel lines, or sheet-metal body
parts.
Connect to a heavy gauge metal part of the frame or engine block.
AFTER COMPLETING STEPS 1-2 FROM CHOSEN GROUND
SYSTEM, CONTINUE TO 3-4
3. Connect charger AC supply cord to electric outlet.
4. When disconnecting charger, disconnect the AC cord first, remove
the clip from vehicle chassis, and then remove the clip from battery
terminal in that order.
C. CHARGING BATTERY REMOVED FROM VEHCILE
CAUTION:
Connect and disconnect the DC output clamps only after
removing the AC plug from the electrical outlet. Never allow the DC
output clamps to touch each other. This may cause a spark.
1. Connect the positive(red) charger clip to the positive (POS, P, +)
post of battery.
2. Then connect the negative (black) charger clip to negative (NEG,
N, -) post of battery.
3. Do not face battery when making the final connection.
4. Connect charger AC supply cord to electric outlet.
5. When disconnecting charger, disconnect the AC supply cord first.
Always disconnect the clamps in the reverse sequence of the