- 13 -
If you have any questions regarding this product, please call our customer service hotline at 1-888-985-7877,
9a.m. – 6 p.m. (EST), Monday – Friday, or email us at
.
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Main burner will
not light
Gas valve may be off
Turn gas valve ON
Fuel tank may be empty
Refill LPG tank
Orifice blocked
Clean or replace orifice
Air in supply system
Purge air from lines. Open gas
lines and depress control knob
for 2-3 mins.
Loose connection
Check all fittings
Igniter fails
Use stick lighter to manually
light
Gas pressure low with valve
open full
Replace cylinder or regulator
New cylinder or 1st ignition
Purge air from lines
Cylinder valve on, no gas
flow
Replace hose/regulator
assembly
AAA Battery behind igniter
button is dead
Replace with a new AAA Battery
Low burner flame
Pressure is low
Replace LPG tank
Tank is low on fuel
Fill LPG tank
Gas hose is kinked
Check & straighten or replace
Control knob at max
Check for obstruction at
passageways and orifices
Burner unit
Carbon on reflector &
emitter screen
Clean components as needed
Thick black smoke
Blockage in burner
assembly--thoroughly clean
burner