16
PROBLEM
CAUSE
SOLUTION
A red led is blinking on the
receiver (0,5 sec. On/0,5
sec. Off)
The temperature sensor in the
transmitter is out of service.
Replace transmitter
A red led is blinking on the
receiver (0,5 sec. On/0,5
sec. Off) and the symbol of
antenna is blinking slowly
on the LCD-screen.
The transmitter is positioned out
of the reception range of the
receiver (temperature sensor of
the receiver will temporarily take
over).
The fire will continue to work. Blinking
will stop when transmitter will be
positioned again in the range of the
receiver
The red led on the receiver
flashes briefly and long
out.
The thermostatic sensor in the
receiver is out of service.
Replace the temperature sensor
The red led on the receiver
is glowing continuously.
The thermostatic sensor in the
receiver is out of service and the
transmitter is positioned out of
reception range of receiver.
Place transmitter again in reception
range.
Reset receiver (see 2.8)
Replace temperature sensor
The fire goes out; the red
led on the receiver is
glowing continuously. And
the receiver peeps 4 times
briefly every 2 sec.
The receiver got overheated
(possible causes are: ventilator
out of service or dirty, glass does
not close properly…)
After cooling down of the receiver, de red
led will goes out and the peeping will
stop. It will be possible to operate again
the fire.
Eliminate cause of overheating.
Only CP visible on the
display
Children protection “CP” is
activated
Switch off “CP”
The fire goes out; the red
led is glowing continuously
The unit is in security device.
Make a reset of the receiver (see 2.8)
2.8.
Reset by failure
When the receiver is in failure (red led glowing continuously) a reset can be executed in two different ways:
-
By pressing on
OFF
on the transmitter
-
By pressing on the
RESET
button of the receiver (receiver has to be in position
REMOTE
or
ON
)
During this operation you will hear it beeping several times shortly.
After being reset, the fire will come in manual OFF position.
The possibility exists that the module is in malfunction if the problem that caused the failure is still present.
2.9.
Informations about keys
Some keys have different functions
depending on whether they are short or long press:
Key
MODE:
press more than 3 sec. To switch from mode
Manua
l to mode
THERMO
Press shortly to switch between mode
THERMO
and
PROGRAM
Key
PROG:
press more than 4 sec. to go to mode
PROGRAM
Press briefly to scroll through program
Key
TIMER:
press more than 2 sec. to program
TIMER
Press briefly to view current time
Key
TIMER
+
FAN
: press more than 5 sec. to activate “CP”
Key
UP
+
PLUS
: press more than 3 sec. to ignite
All times shorter than the specified times are considered to be a short press.