1.1 Introduction

We appreciate your business and your choice of Welker products. The installation, operation, and maintenance liability for this 
equipment becomes that of the purchaser at the time of receipt. Reading the applicable 

Installation, Operation, and 

Maintenance

 (IOM) 

Manuals

 prior to installation and operation of this equipment is required for a full understanding of its 

application and performance prior to use.*

If you have any questions, please call  Welker at 1-281-491-2331.

*The following procedures have been written for use with standard Welker OdorEyes parts and equipment. Assemblies that have been modified may have 

additional requirements and specifications that are not listed in this manual.

1.2 Product Description

The Welker OdorEyes 

AEF-1

 Atmospheric Exhaust Filter is designed to remove mercaptan odor from natural gas exhaust lines at 

stations near or in populated areas. The internal filter media absorb offensive odors from constant or intermittent bleed systems.

Welker may custom design the AEF-1 to suit the particular application and specifications of each customer.

1.3 Specifications

 

The specifications listed in this section are generalized for this equipment. Welker can modify the equipment according to your 

company's needs. 

Please note that the specifications may vary depending on the customization of your equipment.

 Table 1: AEF-1 Specifications

Application

Odor Removal From Natural Gas Exhuast Lines

Materials of Construction

Resilient Composites

Maximum Allowable Operating Pressure

Atmospheric Conditions Only

Temperature Range

0 °F to 140 °F (

-17 °C to 60 °C

)

Inlet Connection

¼" FNPT
½" FNPT
¾" FNPT

SECTION 1: PRODUCT INFORMATION

4

IOM-180

MODEL: AEF-1

REV: A

13839 West Bellfort Street, Sugar Land, TX 77498

welker.com

Service Department 281.491.2331

Summary of Contents for OdorEyes AEF-1

Page 1: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL WELKER ATMOSPHERIC EXHAUST FILTER MODEL AEF 1 DRAWING NUMBER AD837BA MANUAL NUMBER IOM 180 REVISION Rev A 7 20 2019 ...

Page 2: ... logo WelkerScope WelkerJet and OdorEyes are registered trademarks of Welker Inc SAFETY 3 1 PRODUCT INFORMATION 4 1 1 Introduction 4 1 2 Product Description 4 1 3 Specifications 4 1 4 Equipment Diagram 5 2 INSTALLATION OPERATION 6 2 1 Before You Begin 6 2 2 Installation and Operation 6 3 MAINTENANCE 7 3 1 Before You Begin 7 3 2 Replacing the AEF 1 7 APPENDIX 8 A Referenced or Attached Documents 8 ...

Page 3: ...cribed in this manual Correct installation and operation however are the responsibility of the end user Welkerreserves the right to make changes to this manualand allproducts in order to improve performance and reliability BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions forlocal inspector s use IMPORTANT Observe all governing codes and ordinances...

Page 4: ...is designed to remove mercaptan odor from natural gas exhaust lines at stations near or in populated areas The internal filter media absorb offensive odors from constant or intermittent bleed systems Welker may custom design the AEF 1 to suit the particular application and specifications of each customer 1 3 Specifications The specifications listed in this section are generalized forthis equipment...

Page 5: ...1 4 Equipment Diagram Figure 1 Welker AEF 1 Diagram 5 IOM 180 MODEL AEF 1 REV A 13839 West Bellfort Street Sugar Land TX 77498 welker com Service Department 281 491 2331 ...

Page 6: ...ration and Maintenance IOM Manualforthe equipment and company standards forproperequipment arrangement 1 Tube from the natural gas exhaust line to the inlet of the AEF 1 Figure 1 The AEF 1must be installed vertically with the outlet pointing down 2 As necessary open any valve s before the AEF 1 to allow exhaust flow to the AEF 1 3 During operation monitor for the smell of odorized natural gas If t...

Page 7: ... to isolate the AEF 1 from the exhaust flow 2 Remove the AEF 1 from the exhaust line and discard 3 Connect the inlet of the replacement AEF 1 to the natural gas exhaust line Figure 1 The AEF 1must be installed vertically with the outlet pointing down 4 As necessary open any valve s before the AEF 1 to allow exhaust flow to the AEF 1 5 The replacement AEF 1 is now operational SECTION 3 MAINTENANCE ...

Page 8: ...ion and Maintenance IOM Manuals suggested for use with this unit l None Welker drawings and schematics suggested for use with this unit l Assembly Drawing AD837BA APPENDIX A REFERENCED OR ATTACHED DOCUMENTS 8 IOM 180 MODEL AEF 1 REV A 13839 West Bellfort Street Sugar Land TX 77498 welker com Service Department 281 491 2331 ...

Page 9: ...__________________________________________________ ____________________________________________________________________________________________________ ____________________________________________________________________________________________________ ____________________________________________________________________________________________________ ______________________________________________...

Reviews: