background image

13839 West Bellfort Street 

Sugar Land, TX 77498 

281.491.2331 - Office 

welker.com

 

©2014 Welker, Inc. All Rights Reserved. 

 

 

Installation, Operation, and 

Maintenance Manual 

 

Welker

® 

Heat Blanket 

Models 

HBAWEL9 & HBAWEL15 

 

 

Manual No.: IOM-080 

 

The  information  in  this  manual  has  been  carefully  checked  for  accuracy  and  is  intended  to  be  used  as  a  guide  for  the 
installation,  operation,  and  maintenance  of  the  Welker

®

  equipment  described  above.  Correct  operating  and  /  or  installation 

techniques,  however,  are  the  responsibility  of  the  end  user.  Welker

®

  reserves  the  right  to  make  changes  to  this  and  all 

products in order to improve performance and reliability.

  

 
 

 

 

 

 

This manual is intended to be used as a basic installation and operation guide for the Welker

®

 Heat 

Blanket, 

HBAWEL9 & HBAWEL15

. For comprehensive instructions, please refer to the IOM Manuals 

for each individual component. A list of relevant component IOM Manuals is given in the Appendix 
section of this manual. 

Summary of Contents for HBAWEL9

Page 1: ...maintenance of the Welker equipment described above Correct operating and or installation techniques however are the responsibility of the end user Welker reserves the right to make changes to this and all products in order to improve performance and reliability This manual is intended to be used as a basic installation and operation guide for the Welker Heat Blanket HBAWEL9 HBAWEL15 For comprehen...

Page 2: ...IOM 080 Last Updated 10 20 2014 PART HBAWEL9 HBAWEL15 Page 2 of 7 Rev C TABLE OF CONTENTS Welker Welker Jet and WelkerScope are Registered Trademarks owned by Welker Inc ...

Page 3: ... is designed to maintain the set temperature and prevent temperature changes that would affect the integrity of the sample The blanket prevents unwanted condensation from accumulating inside sampling equipment Two thermal layers provide superior temperature protection and create a rugged flexible construction Loop and hook closures fasten the blanket to equipment and Velcro straps close the seams ...

Page 4: ...0VAC Australia 240VAC Area Classification NEC Class I Div 2 Groups B C and D IEC Zone 2 UL Listed Components T Rating T3 The specifications listed in this section are generalized for this equipment Welker can modify the equipment according to your company s needs However please note that the specifications may vary depending on the customization of your product ...

Page 5: ...e heat blanket cable to the terminal strip of the thermostat and then make the terminations from the terminal strip of the thermostat to the power source 7 Turn ON the power source As necessary adjust the thermostat to the desired temperature 8 The blanket is now in operation After unpacking the unit check the equipment for compliance and for any damage that may have occurred during shipment Claim...

Page 6: ... OFF all electrical power 2 Prior to performing maintenance on the equipment wrapped in the heat blanket remove the heat blanket from the equipment 3 The heat blanket should be wiped down with a clean moist cloth when maintenance is performed on the equipment 4 As necessary contact Welker for service options if the thermostat fails The heat blanket does not require maintenance ...

Page 7: ...on and Maintenance IOM Manuals suggested for use with this unit None Other Installation Operation and Maintenance IOM Manuals suggested for use with this unit None Welker drawings and schematics suggested for use with this unit None 13839 West Bellfort Street Sugar Land TX 77498 281 491 2331 Office welker com ...