INDURO 165 OWNERS MANUAL
Page 11
9. GENERAL MAINTENANCE
Before removing the machine cover, ENSURE that the unit is disconnected from the
mains power supply. When the unit is energised LETHAL VOLTAGES are present on the
electrical components enclosed.
The Induro 165 turns the cooling fan off when it is not required to reduce dust
intake. However care should be taken to prevent excessive dust and dirt entering the
welding power source. It is recommended that at regular intervals, according to the
prevailing conditions, the machine covers be removed and any accumulated dust be
removed by the use of dry, low pressure compressed air.
10. FAULT FINDING, NO WELDING CURRENT
Check:
•
That mains supply is available at the INDURO 165 power source. At least one of the
key pad LED’s should be lit. If not, test that the power point works by plugging in
another appliance.
•
That the welding and work leads are connected securely to the output so ckets at the
front of the machine.
•
For continuity of the work lead, work clamp and electrode holder. Loose connections
can prevent proper flow of the welding current.
The INDURO 165 welding power source incorporates an in built protection device
which will trip if the unit is overloaded. In this event, the machine will not deliver welding
current, and the red Over Temp LED will be illuminated. If the thermal overload protection
device has been tripped, leave the machine energised with the fan running to ac hieve the
maximum cooling rate.
If equipment failure is suspected, forward the unit to your nearest authorised WIA
qualified service agent. To find out your nearest qualified service agent call 1300 300 884.