SECTION 9 : MAINTENANCE
WARNING! BEFORE CARRYING OUT MAINTENANCE OPERATIONS MAKE SURE THE WELDING MACHINE
IS SWITCHED OFF AND DISCONNECTED FROM THE MAIN POWER SUPPLY.
EXTRAORDINARY MAINTENANCE:
EXTRAORDINARY MAINTENANCE OPERATIONS SHOULD BE CARRIED OUT ONLY AND EXCLUSIVELY BY
SKILLED OR AUTHORISED ELECTRICAL-MECHANICAL TECHNICIANS.
WARNING! BEFORE REMOVING THE WELDING MACHINE PANELS AND WORKING INSIDE THE MACHINE
MAKE SURE THE WELDING MACHINE IS SWITCHED OFF AND DISCONNECTED FROM THE MAIN POWER
SUPPLY OUTLET.
IF CHECKS ARE MADE INSIDE THE WELDING MACHINE WHILE IT IS LIVE, THIS MAY
CAUSE SERIOUS ELECTRIC SHOCK DUE TO DIRECT CONTACT WITH LIVE PARTS AND/OR INJURY DUE TO
DIRECT CONTACT WITH MOVING PARTS.
SECTION 10 : CIRCUIT DIAGRAM
1
1
2
2
3
3
4
4
5
5
Inspect the welding machine regularly, with a frequency depending on use and the dustiness of the environment, and
remove the dust deposited on the transformer, using a jet of dry compressed air (max. 10 bar).
At the same time make sure the electrical connections are tight and check the wiring for damage to the insulation.
At the end of these operations re-assemble the panels of the welding machine and screw the fastening screws right
down.
Never, ever carry out welding operations while the welding machine is open