4–4
SCANTEAM 3700 Wedge Technical Manual
4.2.1
Prefix and Suffix Examples
Example 1: Add Suffix for Specific Symbology
You want to send a CR (carriage return)ĂSuffix for UPC only.
H
Scan the
Add Suffix
Suffix Selection bar code.
H
The Symbology Chart indicates that the Hex value of UPC is 63". Scan
6
and
3
on the Programming Chart (inside back cover).
H
A CR" is equivalent to 0D" (see the Hex ASCII Chart). Scan
0
and
D
on the Programming Chart.
H
Scan the
Save Current Suffix Changes
Exit Selection bar code.
Example 2: Add Suffix for
ALL
Symbologies
You want to send a CR (carriage return)ĂSuffix for all symbologies.
H
Scan the
Add Suffix
Suffix Selection bar code.
H
The Symbology Chart indicates that the Hex value for All Symbologies
is 99". Scan
9
and
9
on the Programming Chart.
H
A CR" is equivalent to 0D". Scan
0
and
D
on the Programming Chart.
H
Scan the
Save Current Suffix Changes
Exit Selection bar code.
Example 3: Add Prefix for Specific SymbologyĂ/ĂSuffix for
ALL
Symbologies
You want to send a HT (tab)ĂPrefix for UPC only and a CRĂ/ĂLF (carriage
returnĂ/Ăline feed) Suffix for all symbologies.
H
Scan the
Add Suffix
Suffix Selection bar code.
H
The Symbology Chart indicates that the Hex value for All Symbologies
is 99". Scan
9
and
9
on the Programming Chart.
H
A CR" is equivalent to 0D" and an LF" is 0A". Scan
0
,
D
,
0
, and
A
on the Programming Chart.
H
Scan the
Save Current PrefixĂ/ĂSuffix Changes
Exit Selection bar code.
H
Scan the
Add Prefix
Prefix Selection bar code.
H
The Symbology Chart indicates that the Hex value of UPC is 63". Scan
6
and
3
on the Programming Chart.
H
An HT" is equivalent to 09". Scan
0
and
9
on the Programming Chart.
Example 4: To Clear a Specific Prefix Entry
You've programmed the 3700 Wedge to send a CRĂ/ĂLF (carriage returnĂ/Ăline
feed) Prefix for all symbologies (Hex value, 99). This is one Prefix entry. You've
also programmed a #" Prefix for UPC (Hex, 63). You decide that you want to
clear the UPC entry, but not the Prefix entry for all symbologies.
H
Scan the
Clear Specific Prefix
Prefix Selection bar code.
H
The Symbology Chart indicates that the Hex value for UPC is 63". Scan
6
and
3
on the Programming Chart.
Summary of Contents for SCANTEAM 3700 Wedge
Page 1: ...R SCANTEAM 3700 Wedge ...
Page 8: ...iv ...
Page 12: ...1 4 SCANTEAM 3700 Wedge Technical Manual ...
Page 30: ...4 10 SCANTEAM 3700 Wedge Technical Manual ...
Page 60: ...7 2 SCANTEAM 3700 Wedge Technical Manual ...
Page 72: ...10 8 SCANTEAM 3700 Wedge Technical Manual ...
Page 76: ...11 4 SCANTEAM 3700 Wedge Technical Manual ...
Page 80: ...13 2 SCANTEAM 3700 Wedge Technical Manual ...
Page 88: ...A 4 SCANTEAM 3700 Wedge Technical Manual ...
Page 90: ...B 2 SCANTEAM 3700 Wedge Technical Manual ...
Page 96: ...SCANTEAM 3700 Wedge Technical Manual ...
Page 99: ...0 1 2 3 4 5 6 7 8 9 A B C D E F ...
Page 100: ...Skaneateles Falls New York 13153 0187 3700WEDGE TM 4619 Jordan Road RevC P O Box 187 ...