4–12 Configuring the SCANTEAM 3700
Set Code 39 Command Kp
COMMAND
<Kp enable, require checksum, send checksum, minimum
length, maximum length>
Parameter
ASCII Option
Enable
0
no
1
yes
*
Require Checksum
0
no
*
1
yes
Send Checksum
0
no
*
1
yes
Minimum Length
Set from 1 to 48
*
(1)
Maximum Length
Set from 1 to 48
*
(48)
Sending the configuration command
Kp
sets Code 39 and all its parameters:
enable/disable, require checksum, send checksum, minimum length, and maximum
length. The default setting is Code 39 enabled, doesn’t require or send checksum,
minimum length 1, and maximum length 48.
Set Codabar Command Kq
COMMAND
<Kq enable, send start/stop, minimum length, maximum
length>
Parameter
ASCII Option
Enable
0
no
1
yes
*
Send Start/Stop
0
no
1
yes
*
Minimum Length
Set from 1 to 60
*
(6)
Maximum Length
Set from 1 to 60
*
(60)
Sending the configuration command
Kq
sets Codabar and all its parameters:
enable/disable, send start/stop, minimum length, and maximum length. The default
setting is Codabar enabled, send start/stop, minimum length 6, and maximum length 60.