Configuring the SCANTEAM 3700 4–11
Set No Read Message Command Kk
COMMAND
<Kk enable, data>
Parameter ASCII
Option
Enable
0
no
1
yes
*
(NR)
Data
one to seven ASCII characters
Sending the configuration command
Kk
sets the no read message. Any ASCII character
can be specified except NUL, ACK, NAK, DC1, DC2, DC3, DC4 or DEL. The default
setting is NR (no read).
Tip:
The No Read Message is not sent for scanner ports that are configured for a
continuous trigger mode.
Set Votes Command Km
COMMAND
<Km data_global, data_port_1, data_port_2, #>
Parameter ASCII
Option
Data
one or two ASCII digits
range of 1 to 31
*
(3, 1)
Sending the configuration command
Km
sets the votes. One or two ASCII digits in the
range of 1 to 31 determine the number of consecutive identical decodes required for a
valid read. A selection of 1 means that no voting will take place. The default setting is
Data_port_1, 3 and Data_port_2, 1, which means voting is set to 3 for port 1 and set to 1
for port 2.
Tip:
When using the voting feature for additional decode security, a value of three is
generally adequate in most applications.