background image

24

Welch Allyn, Inc.

4341 State Street Road

Skaneateles, NY 13153-0220

Tel: (800) 535-6663

www.welchallyn.com

Regulatory Affairs Representative

Welch Allyn Limited

Navan Business Park

Dublin Road

Navan, County Meath,

Republic of Ireland

Printed in U.S.A.

Material No. 720127 Rev. A

Summary of Contents for PanOptic 118 Series

Page 1: ...PanOptic Ophthalmoscope 118 Series Directions for use...

Page 2: ...www welchallyn com patents 2013 Welch Allyn Inc To support the intended use of the product described in this publication the purchaser of the product is permitted to copy this publication for internal...

Page 3: ...et up Instructions 5 Conducting an Examination with the PanOptic Ophthalmoscope 7 Apertures and Filters 12 The Eye 14 Lamp Replacement Instructions 15 Repairs 16 Cleaning and Disinfection 16 Troublesh...

Page 4: ...iv PanOptic Ophthalmoscope Warranty 20 Specifications 21...

Page 5: ...Instructions for Use Type BF applied part Meets essential requirements of European Medical Device Directive 93 42 EEC Reorder number Product Identifier Manufacturer Date of Manufacture YYYY MM DD Prof...

Page 6: ...e light directed into the patient s eye to the minimum level that is necessary for diagnosis Infants aphakes and persons with diseased eyes are at a greater risk The risk is also increased if the exam...

Page 7: ...should be allowed to cool before removal WARNING Equipment not suitable for use in the presence of a flammable anesthetic Caution Halogen lamps are pressurized to provide maximum efficiency and illum...

Page 8: ...nerve head due to papilledema or optic neuritis In this sense the eye serves as a window through which many valuable clinical evaluations may be made When a preliminary diagnosis of an imminently dan...

Page 9: ...Welch Allyn power sources Push in slightly and turn 90 degrees Attaching the Patient Eyecup to PanOptic Insert eyecup into the patient s side of the instrument Push and twist in one motion until you f...

Page 10: ...ens into patient s side of the instrument Push and twist in one motion until you feel the two lock together as shown on page 5 except replacing Patient Eyecup with the Corneal Viewing Lens Verify that...

Page 11: ...Remove Spectacles preferred but not required 3 Look through the scope from the doctor s side with your thumb on the focusing wheel Focus the scope on an object roughly 15 feet away This procedure will...

Page 12: ...Examiner should be positioned approximately 15 degrees to the temporal side of the patient 7 Instruct the patient to look straight ahead at a distant object 8 Begin from about 6 inches away looking t...

Page 13: ...t s brow 11 Once you have a stable view of the fundus rotate the focusing wheel until you have a crisp view of the optic disc and the vessels surrounding it Note For the largest view compress the eyec...

Page 14: ...which will automatically place the macula in full view Examine for abnormalities in the macular area The red free filter facilitates viewing of the center of the macula or the fovea 13 To examine the...

Page 15: ...ature of PanOptic is that the examiner does not have to switch to his her left eye The practitioner can use either eye to examine either patient eye because of the greater working distance between pat...

Page 16: ...d pupil examination of the eye 3 Micro Spot Aperture Allows easy entry in very small undilated pupils 4 Slit Aperture Models 11810 11820 only Helpful in determining various elevations of lesions parti...

Page 17: ...for the examiner 6 Cobalt Blue Filter Model 11820 only In conjunction with fluorescein dye applied topically to the cornea and an add on magnifying lens included this filter is helpful in detecting co...

Page 18: ...through an add on corneal viewing lens In the same manner vitreous opacities can be detected by having the patient look up and down to the right and to the left Any vitreous opacities will be seen mo...

Page 19: ...maximum efficiency and illumination Mistreatment may cause shattering Protect lamp surface against abrasion and scratches Verify power is off when replacing lamp Dispose of lamp with care ALIGNTAB Use...

Page 20: ...cessively saturate the PanOptic Do not immerse PanOptic in any solution Do not sterilize the PanOptic After disinfection inspect the PanOptic for visible signs of deterioration If evidence of damage o...

Page 21: ...ch Allyn part number 03800 U or 03800 LED The battery handle has completely discharged Charge the handle check the battery and or the charger Spot is not centered The aperture dial is not centered Mov...

Page 22: ...is not fully charged Charge the handle check the battery and or the charger Glare in view Fingerprints or dirt on the objective Patient s Side lens Clean the objective Patient s Side lens with a clea...

Page 23: ...iption Product 1 Corneal Viewing Lens model no 11820 only 11875 2 Patient Eyecups Package of five 5 each 118092 11870 3 Patient s Side Bumper 118051 4 Lamps 03800 U or 03800 LED 5 Chrome Ring 118027 6...

Page 24: ...Welch Allyn will repair or replace the instrument or component s at no cost to the purchaser This warranty only applies to instruments purchased new from Welch Allyn or its authorized distributors or...

Page 25: ...hout eyecup Eyecup 1 45 L Weight 48 lbs without eyecup 50 lb with eyecup Conforms with IEC UL CSA EN 60601 1 ISO 10943 Equipment Classification Equipment not protected against the ingress of water Env...

Page 26: ...22...

Page 27: ...23...

Page 28: ...t Road Skaneateles NY 13153 0220 Tel 800 535 6663 www welchallyn com Regulatory Affairs Representative Welch Allyn Limited Navan Business Park Dublin Road Navan County Meath Republic of Ireland Printe...

Reviews: