Welch Allyn AED 10 Operating Instructions Manual Download Page 13

Operating Instructions

11

Allows the Instructor to select 
AHA Scenario number 3 as the 
default scenario. The Trainer will 
automatically turn off after the 
selection has been made.

Allows the Instructor to select 
AHA Scenario number 4 as the 
default scenario. The Trainer will 
automatically turn off after the 
selection has been made.

Allows the Instructor to select 
AHA Scenario number 5 as the 
default scenario. The Trainer will 
automatically turn off after the 
selection has been made.

Allows the Instructor to select 
AHA Scenario number 6 as the 
default scenario. The Trainer will 
automatically turn off after the 
selection has been made.

Allows the Instructor to select 
AHA Scenario number 7 as the 
default scenario. The Trainer will 
automatically turn off after the 
selection has been made.

Allows the Instructor to select 
AHA Scenario number 8 as the 
default scenario. The Trainer will 
automatically turn off after the 
selection has been made.

1-Shock Protocols

Allows the Instructor to select 
Ventricular Fibrillation with one-
shock conversion. The Trainer will 
automatically turn off after the 
selection has been made.

Allows the Instructor to select 
Ventricular Fibrillation with one-
shock conversion followed by 
refibrillation. The Trainer will 
automatically turn off after the 
selection has been made.

Note:

 Scenarios 11 and 12 are not accessible through remote control, and must be 

accessed through the Scenario Menu.

Current Scenario Shock Protocols

Allows the Instructor to interrupt 
any scenario with a continuous 
shockable rhythm. The current 
default scenario is not changed.

Allows the Instructor to interrupt 
any scenario with a continuous 
non-shockable rhythm. The 
current default scenario is not 
changed.

Other Functions

Allows the Instructor to interrupt 
any scenario with a lead-fault 
condition. To resume the 
scenario, press the button again.

Allows the Instructor to interrupt 
any scenario with a “Motion” 
condition on the next rhythm 
analysis.

Allows the Instructor to interrupt 
any scenario with a Low Battery 
condition. To resume the 
scenario, press the button again.

Allows the Instructor to simulate 
a Warning (flashing icon) system 
status. To resume the scenario, 
press the button again.

Allows the Instructor to pause 
during any scenario. To resume 
the scenario, press the button 
again.

While the Trainer is paused, all 
other buttons are inactive until the 
pause button has been pressed 
again.

Table 3.  Remote Control Buttons (continued)

3

4

5

6

7

8

9

10

Summary of Contents for AED 10

Page 1: ...Welch Allyn AED 10 TM Trainer Operating Instructions Software version 01 04 XX...

Page 2: ...re may not be copied decompiled reverse engineered disassembled or otherwise reduced to human perceivable form This is not a sale of the software or any copy of the software all right title and owners...

Page 3: ...l accurately mimic the operation of the defibrillator and provide a realistic demonstration Twelve different scenarios are available Multiple language selections are available Hand held IR remote cont...

Page 4: ...urrent battery level The Trainer displays text and voice prompts when the battery needs to be changed Note The Battery Level Indicator is only available on Welch Allyn AED 10 defibrillators using soft...

Page 5: ...ng a scenario and continues after the scenario is resumed Battery Level While in Trainer mode the Trainer graphically displays the battery level in the upper middle portion of the screen The battery l...

Page 6: ...ior to entering the Volume menu and returns to the Main Menu Contrast Pressing the Enter button while the Contrast menu item is highlighted displays the Contrast menu allowing the user to select a con...

Page 7: ...splays the CPR menu with CPR Timer highlighted Pressing the Next button highlights CPR Tempo and pressing Next again highlights Back With CPR Timer highlighted pressing the Enter button displays the C...

Page 8: ...f CPR chest compressions per minute options are 90 95 100 105 110 115 120 or Disable The Save menu item saves the currently selected value and returns to the CPR Menu The Cancel menu item restores CPR...

Page 9: ...Defaults Pressing the Enter button while the Restore Default menu item is highlighted displays the restore defaults menu Pressing the Next button scrolls down highlighting the next menu item If the E...

Page 10: ...he Enter button while the Maintenance menu item is highlighted displays the Maintenance Menu This menu is for factory use only Maintenance Service System Test Enter Enter More Menu More Menu Maintenan...

Page 11: ...hm CPR 3 Ventricular fibrillation with two shock conversion Shockable rhythm 2 Shocks Non shockable rhythm CPR Non shockable rhythm CPR 4 Non shockable rhythm Non shockable rhythm CPR Non shockable rh...

Page 12: ...it will flash to indicate that a command has been received The status indicator LED will flash continuously when a scenario has been paused Refer to the diagram and descriptions listed below Table 3...

Page 13: ...the Instructor to select Ventricular Fibrillation with one shock conversion followed by refibrillation The Trainer will automatically turn off after the selection has been made Note Scenarios 11 and 1...

Page 14: ...trol Approximately two years Number of training scenarios 12 Storage temperature without batteries 22 F to 158 F 30 C to 70 C Operating temperature 32 F to 122 F 0 C to 50 C Weight without batteries 1...

Page 15: ...idity should be at least 30 Electrical fast transient burst IEC 61000 4 4 2 kV for power supply lines 1 kV for input output lines Not applicable Not applicable Surge IEC 61000 4 5 1 kV differential mo...

Page 16: ...the frequency range 80 MHz to 2 5 GHz are intended to decrease the likelihood that mobile portable communications equipment could cause interference if it is inadvertently brought into patient areas F...

Page 17: ...79 3 79 7 27 100 11 70 12 00 12 00 23 00 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be determined using the equation applic...

Page 18: ...16 Welch Allyn AED 10 Trainer...