Replacement Bulb Usage
Replacement bulbs are not interchangeable
between LuminIce® and LuminIce® II.
• LuminIce® replacement bulb - K00425
• LuminIce® II replacement bulb - K00454
LUMINICE® II INDICATOR LIGHTS
LuminIce® II has an LED light for status
indication:
• Steady red light = Replace bulb
• Flashing red light = Service is required
• Blue = Normal operation
• Red/Blue flash = Incorrect replacement
bulb has been installed.
Bulb Replacement Frequency
LuminIce® and LuminIce® II bulbs require
replacement on a yearly basis. Although the
bulb will still illuminate after 12 months,
the effectiveness of the bulb diminishes
as operational hours increase. To retain
maximum effectiveness, replace the bulb
on a 12 month schedule.
LuminIce® II has an indicator light that
will illuminate red when the bulb needs
replacement. A remote LED is available
as an accessory (K00455) to allow all
indicators (including the reminder) to be
viewed without removing the ice machine
panels.
LuminIce® Reminder Setup for
Indigo® NXT & Indigo® Model Ice
Machines
Complete display panel navigation is
available in the Indigo® and Indigo® NXT
ice machine Installation, Operation and
Maintenance Manual. Publications for all
Manitowoc equipment is available on our
website www.manitowocice.com.
INDIGO® TOUCHSCREEN MODELS
When a LuminIce® is installed the
touchscreen will display a blue light.
This light will change to red when bulb
replacement is due.
INDIGO® MODELS WITHOUT
TOUCHSCREEN
Perform the procedure below to display a
change-bulb reminder every 12 months.
1. From the Set-Up menu, use the Down
arrow to highlight LuminIce®.
2. Press the Check mark. On this screen,
you can choose to turn the reminder
to AUTO or OFF by highlighting your
choice and pressing the Check mark.
Selecting one will deselect the other.
3. When the check reflects your
preference, use the Down arrow to
navigate to Exit and press the Check
mark. The display will return to the
Set-Up menu.
Section 3