12
Part Number: 000014110 Rev 01 1/19
NOTE: QuietQube models do not have open
terminals on contactor. Remove two wires
from contactor, install supplied electrical
connector and connect wires.
Wires Removed From Contactor
LuminIce® Power
Contactor
L2
L1
3. Test run the ice machine and
LuminIce®. The LuminIce® is energized
whenever power is applied to the ice
machine. A noticeable draft will be
emitted from the upper hose adapter
during operation.
Indigo® NXT or Indigo® Model 48"
Wide Single Evaporator Installation
K00451 Indigo® & K00465 Indigo®
NXT
n
Warning
Disconnect power to ice machine at the
electrical disconnect. Pressing the power
button does not disconnect line voltage.
1. Disconnect all power to the ice
machine at the electrical disconnect.
2. To allow access for LuminIce® tubing,
the plastic caps in the evaporator and
compressor compartment bulkhead
wall must be removed and discarded.
Remove the evaporator dust cover to
access lower cap.
Remove Plastic Caps From Bulkhead In The
Evaporator And Compressor Compartment
Remove Dust Cover