2 of 2
Document Number: GAR_IS_4603400 4/18
Subject:
Replacing the Infinite Switch, from old Robertshaw to the new EGO
NOTE:
In order to connect the same wire to the new
switch, as per the above diagram of equivalence,
follow the steps below:
7. Cut the wire from the old switch.
8. On the piece of wire
remaining on the
harness, strip its end
3/8”.
9. Insert the stripped end of the wire into the
WAGO connector (corresponding the activation
lever lifted of the WAGO connector)
10. Lock the stripped
end of the wire into
the WAGO connector
by lowering its
corresponding
activation lever tab.
11. Insert and lock
one of the wires
provided in the kit
into the same WAGO
connector.
12. Connect the newly installed wire onto its proper
terminal of the new switch provided with the kit,
as per the schematic of equivalence
13. Repeat all the steps above to complete the
whole wiring transfer from the old switch to the
new.
14. Install and secure back the new infinite switch to
the panel and also re-install the panel.
15. Plug in and test the unit.