Section 2
Installation
Part Number: 9291463A 11/21
7
• Do not obstruct the flow of ventilation air. Make sure the
air vents of the equipment are not blocked.
• Air movement in the room will adversely effect ASM
refrigeration. Do not place the model near doors or air
vents.
• Do not install the equipment directly over a drain.
Steam rising up out of the drain will adversely affect
operation, air circulation, and damage electrical /
electronic components.
Weight of Equipment
Model
Weight
ASM-36P
425lbs (193kg)
ASM-48P
500lbs (227kg)
Clearance Requirements
DANGER
Minimum clearance requirements are the same for
noncombustible locations as for combustible locations.
The flooring under the appliance must be made of a
noncombustible material.
DANGER
Risk of fire/shock. All minimum clearances must be
maintained. Do not obstruct vents or openings.
Sides
1” (2.5cm)
• Keep the vents clean and free of obstruction.
Dimensions
Model
Length
Depth
Height
ASM-36P
36.25”
(92cm)
25.93”
(66cm)
63.48“
(161cm)
ASM-48P
48.25”
(123cm)
25.93”
(66cm)
63.48“
(161cm)
Model
Display Storage
ASM-36P
8.2ft
3
ASM-48P
11.3ft
3
These units are installed by placing them into the counter
from above. The counter cutout sizes are as follows.
Model
Counter Cutout Dimensions
ASM-36P
35.13” x 25.50” (89cm x 65cm)
ASM-48P
47.13” x 25.50” (120cm x 65cm)
Model
Louver Cutout Dimensions
ASM-36P
28.00” x 17.00” (71cm x 42cm)
ASM-48P
28.00” x 17.00” (71cm x 42cm)
Model
Control Cutout Dimensions
ASM-36P
6.75” x 4.37” (17cm x 11cm )
ASM-48P
6.75” x 4.37” (17cm x 11cm )