Installation
Section 2
10
Part Number: 9291463A 11/21
LOWER IN THE ASM
5. Remove the stainless steel pans in the bottom of the
unit.
6. Remove the stainless steel pan clip rail below the door
track.
7. Bolt in the lifting plates using the bolts located inside
the tank that are installed in the lifting braces.
8. Slide two 1” steel pipes into the lifting plate holes. Place
forklift forks under the pipes and clamp the forks and
pipes in position.
Lifting Plates and 1” Steel Pipes
9. Raise the unit high enough with the forklift to roll the
base under the unit into position. Lower the ASM unit
into the base using care to clear all of the flanges and
screw heads.
Lifted ASM
10. Remove the bolts and remove the lifting plates. Install
plastic plugs in the bolt holes.
11. Install the stainless steel pan clip rail below the door
track.
12. Install the stainless steel pans in the bottom on the
unit making sure the turn down is engaged in the slot
below the door track.
13. Install the sneeze guard glass in the clips and attach the
end clip with two stainless steel self tapping screws.
14. Use gray silicone to finish the joint between the drop in
unit and the top of the base.
CONSTRUCT AN AIR DUCT
15. Construct an air duct (not provided) connecting
the condenser face to the louver. This will prevent
recirculation of discharge air.
17.00”
(42cm)
E
D
28.0”
(71cm)
10.0”
(25cm)
B
A
Air duct dimensions
to match condenser face
(Fig. 1)
4.37”
(11cm)
6.75”
(17cm)
3.5”(9cm) -
18”(46cm)
18.0”
(46cm)
Max
F
A
C
B
Air Duct Dimensions (Fig. 1)
Dimension
ASM-36P
ASM-48P
A
10.5” (267mm)
13” (330mm)
B
11” (279mm)
11” (279mm)