background image

Part Number: 9294098  01/18 

13

Section 2 

Installation

Refrigeration

Model

BTU/Hour 

Capacity

Heat of 

Rejection

Charge

Refrigerated Front Breathers With Doors

4427N-6

1300

1690

9oz.

4427N-8

4427N-9M

4427N-12M

4432N-12M

1300

1690

9oz.

4448N-8

1300

1690

10oz.

4448N-12

4448N-18M

4460N-8

3600

4680

11oz.

4460N-12

4460N-12M

4460N-18M

4460N-24M

4464N-8

3600

4680

11oz.

4464N-12

4464N-12M

4464N-16

4464N-18M

4464N-24M

4472N-12

3600

4680

11oz.

4472N-18

4472N-18M

4472N-24M

4472N-30M

Refrigerated Front Breathers With Drawers

D4427N-6

1300

1690

9oz.

D4427N-8

D4427N-9M

D4427N-12M

D4432N-12M

1300

1690

9oz.

D4448N-8

1300

1690

10oz.

D4448N-12

D4448N-18M

D4460N-8

3600

4680

11oz.

D4460N-12

D4460N-12M

D4460N-18M

D4460N-24M

D4464N-8

3600

4680

11oz.

D4464N-12

D4464N-12M

D4464N-16

D4464N-18M

D4464N-24M

D4472N-12

3600

4680

11oz.

D4472N-18

D4472N-18M

D4472N-24M

D4472N-30M

Model

BTU/Hour 

Capacity

Heat of 

Rejection

Charge

Refrigerated Front Breathers With Doors & 4” S/S Backsplash

ST4427N-8

1300

1690

9oz.

ST4427N-12M

ST4448N-8

1300

1690

10oz.

ST4460N-8

3600

4680

11oz.

ST4460N-12M

ST4460N-18M

ST4464N-8

3600

4680

11oz.

ST4464N-12

ST4464N-12M

ST4464N-18M

ST4472N-12

3600

4680

11oz.

ST4472N-18M

ST4472N-24M

Refrigerated Front Breathers With Drawers & 4” S/S Backsplash

STD4427N-8

1300

1690

9oz.

STD4427N-12M

STD4448N-8

1300

1690

10oz.

STD4460N-8

3600

4680

11oz.

STD4460N-12M

STD4460N-18M

STD4464N-8

3600

4680

11oz.

STD4464N-12

STD4464N-12M

STD4464N-18M

STD4472N-12

3600

4680

11oz.

STD4472N-18M

STD4472N-24M

Reduced Work Height Refrigerated Front Breathers With Doors

UC4427N-6

1300

1690

9oz.

UC4427N-9M

UC4427N-12M

UC4432N-12M

1300

1690

9oz.

UC4448N-8

1300

1690

10oz.

UC4448N-12

UC4448N-18M

UC4460N-8

3600

4680

11oz.

UC4460N-12

UC4460N-12M

UC4460N-18M

UC4460N-24M

UC4464N-8

3600

4680

11oz.

UC4464N-12

UC4464N-12M

UC4464N-16

UC4464N-18M

UC4464N-24M

UC4472N-12

3600

4680

11oz.

UC4472N-18

UC4472N-18M

UC4472N-24M

UC4472N-30M

Summary of Contents for Delfield 4400 Series

Page 1: ...s Installation Operation and Maintenance Manual This manual is updated as new information and models are released Visit our website for the latest manual Part Number 9294098 01 18 Compact Refrigerators 4400 Series 9294098 ...

Page 2: ...oaked cloths or combustible cleaning solutions for cleaning nWarning This product contains chemicals known to the State of California to cause cancer and or birth defects or other reproductive harm Operation installation and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers crystalline silica and or carbon monoxide Inhalation of airborne particles of g...

Page 3: ... Leg Caster Installation 14 Changing Pan Height 15 Shelf Installation Instructions 15 Optional Overshelf Installation Instructions 15 Standard Cutting Board Bracket Mounting 16 Standard Bracket Adjustment 16 Heavy Duty Cutting Board Bracket Mounting 17 Section 3 Operation Power To Cool 20 Temperature Control 20 Efficient Operation 20 Defrost 20 Evaporator Fan Operation 20 Section 4 Maintenance Int...

Page 4: ... One Door Salad Top 4427N 8 4427N 9M One Door Mega Top 4427N 12M 4432N 12M 4448N 8 Two Door Salad Top 4448N 12 4448N 18M Two Door Mega Top 4460N 8 Two Door Salad Top 4460N 12 4460N 12M Two Door Mega Top 4460N 18M 4460N 24M 4464N 8 Two Door Salad Top 4464N 12 4464N 12M Two Door Mega Top 4464N 16 Two Door Salad Top 4464N 18M Two Door Mega Top 4464N 24M 4472N 12 Three Door Salad Top 4472N 18 4472N 18...

Page 5: ...Door Salad Top UC4427N 9M One Door Mega Top UC4427N 12M UC4432N 12M UC4448N 8 Two Door Salad Top UC4448N 12 UC4448N 18M Two Door Mega Top UC4460N 8 Two Door Salad Top UC4460N 12 UC4460N 12M Two Door Mega Top UC4460N 18M UC4460N 24M UC4464N 8 Two Door Salad Top UC4464N 12 UC4464N 12M Two Door Mega Top UC4464N 16 Two Door Salad Top UC4464N 18M Two Door Mega Top UC4464N 24M UC4472N 12 Three Door Sala...

Page 6: ...ont to back nWarning This equipment is intended for indoor use only Do not install or operate this equipment in outdoor areas The location selected for the equipment must meet the following criteria If any of these criteria are not met select another location Units are intended for indoor use only The location MUST be level stable and capable of supporting the weight of the equipment The location ...

Page 7: ...8 D4472N 18M D4472N 24M D4472N 30M Model Ship Weight Refrigerated Front Breathers With Doors 4 S S Backsplash ST4427N 8 240lbs 109kg ST4427N 12M 223lbs 101kg ST4448N 8 316lbs 143kg ST4460N 8 411lbs 186kg ST4460N 12M ST4460N 18M ST4464N 8 421lbs 191kg ST4464N 12 ST4464N 12M ST4464N 18M ST4472N 12 461lbs 209kg ST4472N 18M ST4472N 24M Refrigerated Front Breathers With Drawers 4 S S Backsplash STD4427...

Page 8: ...g able to flow freely through the front louver The louver at the back of the cabinet is not necessary for proper operation but any air flow through it is beneficial Caution Any restriction of the proper air flow outlined above total or partial will void the warranty on the cabinet Dimensions Model Length Depth Work Height Refrigerated Front Breathers With Doors 4427N 6 27 69cm 31 50 80cm 36 00 91c...

Page 9: ...4460N 24M UC4464N 8 64 163cm 31 50 80cm 34 25 87cm UC4464N 12 UC4464N 12M UC4464N 16 UC4464N 18M UC4464N 24M UC4472N 12 72 183cm 31 50 80cm 34 25 87cm UC4472N 18 UC4472N 18M UC4472N 24M UC4472N 30M Model Length Depth Work Height Reduced Work Height Refrigerated Front Breathers With Drawers UCD4427N 6 27 69cm 31 50 80cm 34 25 87cm UCD4427N 9M UCD4427N 12M UCD4432N 12M 32 81cm 31 50 80cm 34 25 87cm ...

Page 10: ...3 572L STD4460N 12M 12 STD4460N 18M 18 STD4464N 8 8 NA 21 60ft3 612L STD4464N 12 12 STD4464N 12M 12 STD4464N 18M 18 STD4472N 12 12 NA 24 80ft3 702L STD4472N 18M 18 STD4472N 24M 24 Model 1 6 Pan Capacity Shelf Area Base Volume Reduced Work Height Refrigerated Front Breathers With Doors UC4427N 6 6 3 17ft2 2945cm2 8 20ft3 232L UC4427N 9M 9 UC4427N 12M 12 UC4432N 12M 12 3 88ft2 3605cm2 10 10ft3 286L ...

Page 11: ...umably to ground Welbilt does not recommend the use of GFCI GFI circuit protection to energize our equipment If code requires the use of a GFCI GFI then you must follow the local code The circuit must be dedicated sized properly and there must be a panel GFCI GFI breaker We do not recommend the use of GFCI GFI outlets to energize our equipment as they are known for more intermittent nuisance trips...

Page 12: ...12 UC4460N 12M UC4460N 18M UC4460N 24M UC4464N 8 12 1 2 115 60 1 5 15P UC4464N 12 UC4464N 12M UC4464N 16 UC4464N 18M UC4464N 24M UC4472N 12 12 1 2 115 60 1 5 15P UC4472N 18 UC4472N 18M UC4472N 24M UC4472N 30M Model Amp H P Voltage Cycle Phase NEMA Plug Reduced Work Height Refrigerated Front Breathers With Drawers UCD4427N 6 7 2 1 5 115 60 1 5 15P UCD4427N 9M UCD4427N 12M UCD4432N 12M 7 2 1 5 115 6...

Page 13: ...472N 30M Model BTU Hour Capacity Heat of Rejection Charge Refrigerated Front Breathers With Doors 4 S S Backsplash ST4427N 8 1300 1690 9oz ST4427N 12M ST4448N 8 1300 1690 10oz ST4460N 8 3600 4680 11oz ST4460N 12M ST4460N 18M ST4464N 8 3600 4680 11oz ST4464N 12 ST4464N 12M ST4464N 18M ST4472N 12 3600 4680 11oz ST4472N 18M ST4472N 24M Refrigerated Front Breathers With Drawers 4 S S Backsplash STD442...

Page 14: ...to make sure the unit will not rock lean or be unstable Cabinets with casters must have the caster brake set so the cabinet cannot move Leg Caster Installation DANGER Legs or casters must be installed and the legs or casters must be screwed in completely to prevent bending When casters are installed the mass of this unit will allow it to move uncontrolled on an inclined surface These units must be...

Page 15: ...upport bracket If the lower pan position is desired for models 4427N 8 or 4427N 12M model specific brackets must be ordered They will replace all other brackets Shelf Installation Instructions 1 Notice the shelves have four alignment pins on the underside and a backstop on the top back 2 Insert the shelves into the cabinet The backstop should be at the top back The alignment pins should be in fron...

Page 16: ...moved screws 5 Remove two screws from one end 6 Place the bracket and secure with the two removed screws 7 Repeat at the other end 8 Insert the cutting board into the brackets back first Lay it down with the holes over the alignment pins Standard Bracket Adjustment Slotted hole provides adjustability of pin for alignment with cutting board holes To adjust loosen acorn nut on bottom side of bracket...

Page 17: ...2 Screw flat head 9324092 2 Fender Washer 9324043 Parts Included For 48 Units Qty Description Part No 1 Left Bracket Varies 1 Center Bracket Varies 1 Right Bracket Varies 1 Silicone 9291311 3 Screw pan head 9321519 3 Screw flat head 9324092 3 Fender Washer 9324043 Parts Included For 60 64 72 Units Qty Description Part No 1 Left Bracket Varies 2 Center Bracket Varies 1 Right Bracket Varies 1 Silico...

Page 18: ...324043 and one pan head screw 9321519 Some adjustment to align the brackets may be necessary once the cutting board is installed Do not over tighten the screws Face 3 Install the cutting board onto the brackets Make final bracket adjustments so the cutting board sits flush in the brackets Tighten screws 4 Silicone 9291311 each bracket anyplace it touches the top or face of the unit This prevents f...

Page 19: ... storage compartment of this appliance nWarning The operator of this equipment is solely responsible for ensuring safe holding temperature levels for all food items Failure to do so could result in unsafe food products for customers nWarning Overloading shelves can damage equipment or cause bodily injury nWarning Damp or wet hands may stick to cold surfaces nWarning Do not block the supply and ret...

Page 20: ...net Continuous opening and closing of the door will hamper the cabinet s ability to maintain optimum refrigeration temperature Top section is not intended for overnight storage Product should be removed from pans Pans can remain in cabinet while empty Defrost The electronic temperature controller monitors evaporator temperature and compressor run time to determine the proper time for a positive de...

Page 21: ...ainted surfaces Caution Maintenance and servicing work other than cleaning as described in this manual must be done by an authorized service personnel Caution Over shelves and other items mounted to the top of the counters should never be installed in the field due to the potential damage to the refrigeration system Responsibility You are responsible for maintaining the equipment in accordance wit...

Page 22: ...lecting underneath the unit make sure the end of the drain tube is in the condensate evaporator The leveling of the unit is important as the units are designed to drain properly when level Be sure all drain lines are free of obstructions Drawer Assembly Cleaning The drawer assembly is designed to be cleaned easily Both drawer and tracks are removable without tools The drawer tracks are dishwasher ...

Page 23: ...ain a clean condenser coil can initially cause high temperatures and excessive run times Continuous operation with a dirty or clogged condenser coil can result in compressor failure Neglecting the condenser coil cleaning procedures will void any warranties associated with the compressor and cost to replace the compressor Doors Hinges Over time and with heavy use doors the hinges may become loose I...

Page 24: ...8 Welbilt provides the world s top chefs and premier chain operators or growing independents with industry leading equipment and solutions Our cutting edge designs and lean manufacturing tactics are powered by deep knowledge operator insights and culinary expertise All of our products are backed by KitchenCare our aftermarket repair and parts service CLEVELAND CONVOTHERM DELFIELD FITKITCHEN FRYMAS...

Reviews: