6 Replacing components
Merrychef conneX
®
service and repair manual
68
LED Drive Status
Flash rate
Additional details
Recovery
Normal Operation (Run)
On Continuously
Fan motor operating normally
10s
Overload (Hardware Current >10A)
1
Fan motor off (switched off in less than 1ms)
10s
Overload (Software Current >3.5A)
2
Fan motor off (switched off after 5s)
10s
Output Phase Missing
3
Fan motor off (switched off after 2s)
10s
Lock Motor
3
Fan motor off (switched off after 2s)
10s
Over Voltage (>275VAC)
5
Fan motor running in safe mode (1000rpm)
10s
Under Voltage (<150VAC)
6
Fan motor running in safe mode (1000rpm)
10s
P1 – P2 link wire missing
7
Fan motor off (switched off in 100ms)
10s
Onboard Fuse Blown
2 then 3
Fan motor off (switched off after 55ms)
10s
Convection fan: motor speed controller control voltages & link positions
Link positions are factory pre-set based on the model
of convection fan used in the conneX ovens. The link
positions must not be altered without express
instruction from Merrychef.
Convection fan: motor and motor speed controller tests
Ensure the following requirements have been met before starting the test:
The appliance has been disconnected from the power supply and protective measures have been taken to ensure
the power cannot be switched on again.
The appliance is cool.
The high voltage capacitors are discharged before commencing work.
Anti-static precautions have been taken.
The casing of the appliance has been removed.
Check the following:
1.
All associated wiring and connections, from IO board X113 & X519 through the speed controller to the convection
fan motor.
2.
Convection fan motor thermal cut-out (IP), two black wires.
3.
Convection fan motor rotates freely / not seized.
4.
Convection fan motor winding resistances:
Blue-red 7.5 Ω
±
10%
Red-yellow 7.5 Ω
±
10%
Yellow-blue 7.5 Ω
±
10%
Blue or red or yellow to earth (open circuit).
5.
With the oven panels refitted and the oven re-connected to the power supply check the fan speeds using visual view
in the service mode.
Oven
Variant
13A & 15A/16A
30A
Input %
0 - 10 Volts
10
2
2
20
2.8
2.8
30
3.5
3.5
40
4.3
4.3
50
5
5
60
5.5
6
70
6
7
80
6.5
8
90
7
9
100
7.5
10