5 Service information
Merrychef conneX
®
service and repair manual
53
E111: Cavity
Sensor Failure
UI displays;
E111
Cavity Sensor
Failure. Please
contact your
Merrychef service
partner to
resolve.
Cavity
thermocouple
damaged or
unplugged
(open circuit).
Check that the thermocouple is correctly fitted and secure on to the IO board
connection X530.
If the thermocouple generates erratic values, or is more than 25
o
C out of range, it
will need to be replaced if the connection is in good condition and intact.
If the fault reoccurs after replacing the thermocouple, replace the IO board.
Check the error log. If the cavity temp reads 328
o
C the sensor was open circuit or
not connected. A closed circuit will register the IO board temperature and will not
generate the E111 error.
E112: IO BOARD
TEMP SENSOR
UI displays;
E112
IO Board
Temperature
sensor failure.
Please contact
your Merrychef
service partner to
resolve.
Ambient
temperature
sensor failure
on the IO
board
IO board failure. Replace IO board (Don’t forget to remove the old PM chip and
insert into the new IO board). Download the up to date firmware from
merrycheftechnical.com
and load on to the oven if required
E113:
MAGNETRON
ON WITHOUT
REQUEST
UI displays;
E113
Microwave On
Without Request.
Please contact
your Merrychef
service partner to
resolve.
A current draw
>1A detected
on the IO
board when
the microwave
circuit is
switched off
IO board failure. Replace IO board (Don’t forget to remove the old PM chip and
insert into the new IO board). Download the up to date firmware from
merrycheftechnical.com
and load on to the oven
E116: Heater
Not Responding
UI displays;
E116
Heater not
responding.
Please contact
your Merrychef
service partner to
resolve.
The oven
asked for
heating, but
did not reach
100
o
C within
30 minutes
Check all the connections are in good condition and secure, from the incoming
power supply through the Filter, Fuses F3 & F4, IO board and the heating element.
The heater element rarely fails, checking all of the connections first is imperative.
Ensure you counter hold the rear bolt of the element connections before tightening
the front nut on the element.
Lastly replace IO board