Operating Instructions

 

 

Control card TS002

 

 

Control card TS003

 

 

Control card TS004

980-200117001 / EN

   

 

 11/2007

Technology that inspires

Summary of Contents for TS 002 E

Page 1: ...Operating Instructions Control card TS002 Control card TS003 Control card TS004 980 200117001 EN 11 2007 Technology that inspires...

Page 2: ...or printing errors in this document We accept no liability for damages directly or indirectly related to the provision or use of this documentation This does not include damages arising from death per...

Page 3: ...s 8 3 2 Terminal connection 9 4 Description of the Inputs and Outputs 10 4 1 Inputs 10 4 2 Outputs 12 5 Operating Controls 13 6 Installation Instructions 15 6 1 Card holder 15 6 2 Terminal PCB 15 6 3...

Page 4: ...ions must be kept in a safe place for further use and must be passed on to every subsequent owner user and end customer The indexing table with the control card may only be started up when the whole m...

Page 5: ...ust be installed in accordance with these regulations The control card must be protected against impermissible use It contains components which are electrostatically sensitive and which can easily be...

Page 6: ...these terminals require a functioning circuit In the case of an EMERGENCY STOP interrupt the following lines Motor line between the contactor and the motor Terminal 2 RESET STOP on the control card D...

Page 7: ...turn switch This allows the drive to proceed to an ideal starting position for the next cycle The drive must come to a standstill within the locking phase This is monitored by the control card and in...

Page 8: ...Digital outputs Output current 100 mA outputs 4 6 7 8 9 10 Output current 2 0 A outputs C D E EMV according to EC directive 89 336 EEC Applicable harmonised standards EN 61 000 3 harmonic current emi...

Page 9: ...1 activ Input 24V 18B 6 Alarm Position overrun Output 24V 100mA 10B 7 Alarm Drive time timeout Motor overload Output 24V 100mA 10A 8 Sum of alarms Output 24V 100mA 9A B 9 Start permitted Output 24V 10...

Page 10: ...the control card alone does not fulfil the requirements for the specification of EMERGENCY STOP and door circuits as it requires a functioning wiring In order to achieve the full EMERGENCY STOP functi...

Page 11: ...ions The jumper N 2H must be inserted on the right Terminal 3 will have no effect Danger Danger Input Terminal H on the control card alone does not fulfil the requirements for the specification of EME...

Page 12: ...It also includes the alarm at output 6 and 7 Reset the alarm with a LOW signal at input 2 Terminal 9 Start permitted Signals HIGH as soon as a new start is permitted Terminal 10 Table in position Thi...

Page 13: ...tor however continues for a short time In order to time optimize the cycles of the indexing table the motor should only be stopped at the end of the cam Otherwise on each cycle the time which the moto...

Page 14: ...in one of the outputs clamps flashes when motor temperature is too high Motor overload lights when the cycle has not reached the in position sensor signal within 9 seconds i e when there is no stop 9...

Page 15: ...ing terminals on the left and right hand sides for the connection of the 24V and the control wires 6 2 Terminal PCB single terminal PCB screw fixing The PCB terminal is designed for installation screw...

Page 16: ...16 Versions without door with door front panel mounting installation fixing onto din rails screw fastening...

Page 17: ...he motor name plate for the dimensioning of the motor protection switch The motor line is a simple non screened line 4 x 1 5 mm There are three versions of the electrical contactor 7 2 Motor line one...

Page 18: ...LOW HIGH HIGH Indexer does not arrive within the timeout period 10 sec Rotating plate is restricted E STOP contactors have switched off the motor E STOP contactors are no longer providing the right co...

Page 19: ...onformity with the EC Machine Guideline of the total machine in which this product is installed has been declared 98 37 EG 73 23 EWG Machinery directive Low voltage directive DIN EN 60034 DIN EN 60204...

Page 20: ...e plate Schematic one direction U V W PE 10 H T 9 8 7 6 5 4 3 2 1 230V 400V Table in position Start permitted Sum of alarms Alarm Timeout overload Motor ON Brake Sensor Alarm Position overrun Automati...

Page 21: ...r name plate U V W PE 10 H T 9 8 7 6 5 4 3 2 1 230V 400V Electronic relay Two direction oscillating Table in position Start permitted Sum of alarms Alarm Timeout overload Alarm Position overrun Automa...

Page 22: ...22 Notes...

Page 23: ...www amadea hu Poland IGIS Automatyzacja Sp z o o PL 30 663 Krak w Phone 48 0 12 278 12 96 Fax 48 0 12 278 12 97 Internet www igis com pl Portugal Fluidotronica Equipamentos Industriais Lda 3720 148 Ol...

Page 24: ...www grafikus de WEISS 11 2007 980 200117001 WEISS GmbH Sondermaschinentechnik Siemensstra e 17 D 74722 Buchen Telephone 49 0 6281 5208 0 Fax 49 0 6281 5208 99 info weiss gmbh de www weiss gmbh de...