Installation and operating instruction
Oil burner WL5/2-B
7 Commissioning
83272202 1/2019-04 La
28-76
7.1.2 Setting values
Set mixing head relative to the combustion heat rating required. For this, the dif-
fuser setting and the air damper setting should be matched.
Determine diffuser setting and air damper setting
Do not operate the burner outside of the capacity graph.
Determine the diffuser setting (dimension X) and air damper setting required
from the diagram and note down.
Example
Burner capacity required
47 kW
Diffuser setting (dimension X)
10.9 mm
Air damper setting
8.5
Diffuser default settings
4
5
6
7
8
9
10
11
12
13
14
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
3
2
1
1
Combustion heat rating [kW]
2
Diffuser settings (dimension X) [mm]
Air damper default settings
2
1
4
5
6
7
8
9
10
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
1
Combustion heat rating [kW]
2
Air damper setting