Installation and operating instruction
Oil burner WL10/1-D 1LN
4 Installation
83299302 1/2019-04 La
19-80
4.2 Selecting a nozzle
Determine nozzle size.
Recommended nozzles
Make
Characteristics
Steinen
60°H
Fluidics
60°HF
Pump pressure setting
9 …
10
… 11 bar
Spray characteristic and spray angle varies depending on pump pressure.
Nozzle selection table
Different load values are possible due to tolerances.
Burner capacity [kW] at pump pressure
Nozzle size [gph]
9 bar
10 bar
11 bar
0.65
–
29.8
30.9
0.75
32.1
33.3
35.7
0.85
36.9
38.1
40.5
1.00
42.8
45.2
47.6
1.10
47.6
49.5
52.4
1.25
53.6
55.9
–
Conversion of burner capacity to oil throughput see formula below.
Oil throughput in kg/h =
Burner capacity in kW
11.9 kWh/kg