Considerations 

 

in the controller to ensure that all writable registers that control critical 

parts of plant or machinery have limit checks built into the program, with 

an out-of-limit safe shut down procedure to ensure safety of personnel. 

ICS 3-304.81 Safety Recommendations: 

     

Consideration should be given to the use of an emergency stop function, which is independent of the programmable 

controller. 
      Where the operator is exposed to the machinery, such as in loading or unloading a machine tool, or where the machine 
cycles automatically, consideration should be given to the use of an electromechanical override or other redundant means, 
independent of the programmable controller, for starting and interrupting the cycle. 
      If provision is required for changing programs while the equipment is in operation, consideration should be given to the 
use of locks or other means of assuring that only authorized personnel can make such changes. 
      These recommendations are intended as safeguards against the failure of critical components and the effects of such 
failures or the inadvertent errors that might be introduced if programs are changed while the equipment is in operation. * 

 

z

 

The ICS 3-304.81 Safety Recommendations are reproduced by permission of the National Electrical 

Manufacturers Association from NEMA ICS 3-304 

2.3 Communications Connections 

The ports as you look at the back of the case, are the ports for connecting to a PLC or some external 

device (Controller Connectors).   

Cable 

Requirements 

Different cables are required for various devices. 

 

Caution 

Restrict cable length to less than 500’ (150m) for RS485 2wire or 4wire 

devices and 50’ (15m) for RS232 devices to avoid communications 

problems.  
The COM light on the front of the MT-600 will turn on with each 

communication. 
Shielded cable must be used for long lengths or cables run in an electrically 

noisy environment. 
Do not run cables next to AC power lines or near sources of electrical noise.   
Be sure that the cable ends have been inserted all of the way into mating 

connectors and are secure 

 

2.3.1 Connector COM1 [RS232] 

 

Pin Designations 

 

 

COM1 [RS-232]

 

Pin assignment of the 9 Pin, Male, SUB-D, COM1 [RS-232] Port. 

Pin# Symbol  Function 

DCD 

Data Carrier Detect 

2 RxD  Received 

Data 

3 TxD  Transmitted 

Data 

4 DTR  Data 

Terminal 

Ready 

5 GND  Signal 

Ground 

DSR 

Data Set Ready 

RTS 

Ready to send output 

CTS 

Clear to send input 

9 RI 

Ring 

Indicator 

Summary of Contents for EasyView MT-600 Series

Page 1: ...en tested to conform to European CE requirements This means that the circuitry is designed to resist the effects of electrical noise This does not guarantee noise immunity in severe cases Proper wire...

Page 2: ...le gases vapors or dusts z The unit should not be installed where fast temperature variations and or high humidity are present This will cause condensation of water in the device z Do not install thes...

Page 3: ...st always be large enough to carry the maximum short circuit current of the path being considered Ground conductors should be connected to a tree from a central star earth ground point This ensures th...

Page 4: ...ht be introduced if programs are changed while the equipment is in operation z The ICS 3 304 81 Safety Recommendations are reproduced by permission of the National Electrical Manufacturers Association...

Page 5: ...5 Pin assignment of the 9 Pin Female SUB D COM3 RS 485 Port Pin Symbol RS 485 4wire RS 485 2wire 1 2 Tx Transmitted Data Data 3 Tx Transmitted Data Data 4 Rx Received Data 5 Rx Received Data 6 GND Sig...

Page 6: ...EC electromagnetic emissions and immunity z Machinery Directive 89 392 EEC 91 368 EEC 93 44 EEC 93 68 EEC machine safety z MT500 products will be CE marked to indicate compliance with the EMC Directiv...

Page 7: ...Hz DRAM 64MB Storage 32MB Flash memory on board 1 CompactFlash card slot RTC Yes General Specification Input Power 21 25 VDC Power Consumption 350 mA 24VDC CE Complies with EN50081 2 and EN50082 2 sta...

Page 8: ...B client b Sound ports h USB Master c MIC ports i Com1 RS232 d Ethernet port RJ 45 j Com2 RS232 e Fuse k Com3 RS485 f Power connector Front View Side View Cutout dimensions MT 608S 222mm 8 74 W x 167m...

Reviews: