cMT-CTRL01 User Manual
V1.0.1
34
2.
Select Weintek Built-in CODESYS. CODESYS software provides 6 languages that can be
selected in [PLC_PRG in:] drop-down list as shown below. Structure Text (ST) is used as an
example in this manual.
3.
Double-click on Device (Weintek Built-in CODESYS) to open the settings window.
4.
Open Scan Network tab, CODESYS software will start searching for the CODESYS devices
on the same network. Select the desired device and then click [OK] to leave. The last two
IP address parts (between dots) are converted into HEX digits and shown in this window.
For example, if the IP address of the CODESYS device is 192.168.2.118, please select
HMI
Name[0276]
. After clicking Wink button, CPU RUN LED flashes for three times.
Summary of Contents for cMT CTRL01