Weil-McLain SVF 1500-3000 Series User'S Information Manual Download Page 2

SVF

 

Series 1

 

Commercial Condensing Gas-Fired Water Boiler

 - User’s Information Manual

2

Part number 550-100-251/0819

The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels or to 

important information concerning the life of the product.

  Indicates presence of hazards that will 

cause severe personal injury, death or 

substantial property damage.

  Indicates presence of hazards that can 

cause severe personal injury, death or 

substantial property damage.

  Indicates presence of hazards that will 

or can cause minor personal injury or 

property damage.

  Indicates special instructions on 

installation, operation or maintenance 

that are important but not related to 

personal injury or property damage.

Hazard definitions

How to use this manual . . .

To . . .

Read/use . . .

See pages . .

Learn precautions

Warnings and definitions

1 – 3

Start or shutdown the 
boiler

Use the OPERATING INSTRUCTIONS

4

Identify and locate boiler 
components & the control 
display

These illustrations and call outs will show you the location of 
main components and use of the control display.

5 – 8

Prevent air contamination

Read the list of air contaminants you must avoid.

If found, either remove the products permanently, or have 
your installer relocate boiler vent and air terminations to an 
uncontaminated area.

9

Maintain the boiler

Maintain the boiler using the schedule in this manual.

Schedule an annual start-up by a qualified service technician 
before every heating season.

9 – 15

The Boiler manual is for use only by a qualified heating 

installer/service technician. Refer only to this User’s Infor-

mation Manual for your reference. Improper installation, 

adjustment, alteration, service or maintenance can cause 

property damage, personal injury (exposure to hazardous 

materials) or loss of life. Installation and service must be 

performed by a qualified installer, service agency or the gas 

supplier (who must read and follow the supplied instruc-

tions before installing, servicing, or removing this boiler. 
This boiler contains materials that have been identified as 

carcinogenic, or possibly carcinogenic, to humans).

When calling or writing about the 

boiler— Please have the boiler model 

number from the boiler rating label and 

the Consumer Protection (CP) number 

from the label located on the back of the 

boiler.

Boiler service and maintenance

Summary of Contents for SVF 1500-3000 Series

Page 1: ...y other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any telephone in your building Immediately call your gas supplier from a n...

Page 2: ...and use of the control display 5 8 Prevent air contamination Read the list of air contaminants you must avoid If found either remove the products permanently or have your installer relocate boiler ve...

Page 3: ...e to boiler personnel and or property may result Continual fresh makeup water will reduce boiler life Mineral build up in boiler heat exchanger reduces heat transfer over heats the metal and causes he...

Page 4: ...er See next page for location of interior boiler manual gas valve External manual gas valve Union Drip leg From gas supply Boiler gas connection Internal manual gas valve SVF Series 1 Commercial Conde...

Page 5: ...iler ON OFF switch Boiler gas connection Screen display use to monitor boiler operation change heating system setpoints and enable disable burner Boiler gas connection Boiler gas connection Screen dis...

Page 6: ...SVF Series 1 Commercial Condensing Gas Fired Water Boiler User s Information Manual 6 Part number 550 100 251 0819 The Control display Figure 4 SVF TM boiler s control display...

Page 7: ...month date year hour and minutes 2 Keeping the date and time current makes sure the control can record problems ac curately Figure 7 SVF TM boiler control display Maintenance notice screens BOILER STA...

Page 8: ...eset boiler as shown below To reset Press the DOWN or RIGHT arrow The display will go to the STATUS screen SETTINGS will be highlighted Press the DOWN arrow to move down to MANUAL RESET Press ENTER ce...

Page 9: ...nto the building Pleasereadtheinformationlistedbelow Ifcontaminatingchemicalswillbepresentnearthelocationoftheboiler combustionairinlet haveyourinstallerpipetheboilercombustionairandventtoanotherlocat...

Page 10: ...ure gauge Verify boiler front door is securely closed MONTHLY Check vent piping Check air piping Check relief valve Check condensate drain system Check automatic air vent PERIODICALLY Test low water c...

Page 11: ...ed and started annually at the beginning of the heating season by a qualified service technician In addition the maintenance and care of the boiler listed on Figure 9 page 10 and explainedinthismanual...

Page 12: ...iately or the boiler combustion air and vent termination must be relocated to another area Check the pressure temperature gauge 1 Make sure the pressure reading on the boiler pressure tempera turegaug...

Page 13: ...line and refill the condensate trap if problem persists regularly Under some circumstances an SVFTM vent system may not produce enough condensate to keep the condensate trap full of liquid If the tra...

Page 14: ...red indicat ing a low water condition 4 The SVF TM boiler s control will shut down the boiler on manual reset 5 The control display will flash red as shown in Figure 8 page 8 6 Select MANUAL RESET to...

Page 15: ...charge pipe to ensure that the valve does not weep after the line has had time to drain If the valve weeps lift the seat again to attempt to clean the valve seat If the valve continues to weep afterwa...

Page 16: ...SVF Series 1 Commercial Condensing Gas Fired Water Boiler User s Information Manual...