Hazard definitions

The following defined terms are used throughout this manual to bring attention to the presence of hazards of
various risk levels or to important information concerning the life of the product.

IMPORTANT! — Read this page first

! ! !

Indicates presence of hazards that will
cause severe personal injury, death or
substantial property damage.

Indicates presence of hazards that can
cause severe personal injury, death or
substantial property damage.

Indicates presence of hazards that will
or can cause minor personal injury or
property damage.

Indicates special instructions on
installation, operation or maintenance
that are important but not related to
personal injury or property damage.

Read and follow instructions below to install or service the burner to reduce risk of severe personal
injury, death or substantial property damage.

Appliance must be connected to a flue with
sufficient draft at all times to assure proper
operation.

Do not use crankcase drainings or any oil
containing gasoline as it is more combus-
tible than No. 1 or No. 2 fuel oil.

Do not attempt to start burner when excess
oil has accumulated in combustion cham-
ber, when boiler is full of vapor, or when
combustion chamber is very hot.

Always keep manual fuel supply valve shut
off if burner is shut down for an extended
period of time.

Do not start burner unless flue collector
hood, jacket cap, flue cap and burner
mounting door are secured in place.

Never burn garbage or paper in the appli-
ance.

Never leave combustible material around
appliance.

Summary of Contents for QB-180

Page 1: ...personal injury death or substantial property damage Burner Manual Oil Burners Series 2 QB 180 300 Read all instructions before installing Installer Leave all documentation with burner for future refe...

Page 2: ...hat are important but not related to personal injury or property damage Read and follow instructions below to install or service the burner to reduce risk of severe personal injury death or substantia...

Page 3: ...Burner Manual Hazard definitions 2 Table of contents 3 Pre installation considerations 4 Burner installation 5 Fuel pumps and oil lines 8 Wiring operation and service 11 Troubleshooting 12 Parts list...

Page 4: ...feet per 1 000 Btuh input of all appliances in space two permanent open ings must be provided One near the top of the enclosure One near the bottom Each opening must have a free area of not less than...

Page 5: ...Wrench Adjustment Cam Captive Screw Electrode Assembly Top Leg of Spinner Centered Vertically Between Electrodes Nozzle Spinner Assembly Spinner Clamping Screw Nozzle Adapter GUN ASSEMBLY Includes E C...

Page 6: ...hten to 110 in lbs 2 Nozzle types A AH H hollow SS semi solid B ES R S AS solid 3 Suggested settings are for set up with listed nozzle sizes only Final adjustments must be made with combustion test eq...

Page 7: ...ten screw holding housing cover plate in place 5 Mount burner to boiler with gasket supplied 6 Verify attenuating air band setting See Table 1 page 6 and Figure 4 Figure 4 Attenuating air band setting...

Page 8: ...et side of pump Pressure over 3 psi may damage shaft seal and allow it to leak oil Solenoid valve Solenoid valve supplied in nozzle line is a non delay valve and provides instant oil supply shutoff to...

Page 9: ...a single stage or two stage burner fuel pump Burner fuel pump bypass plug must not be used with one pipe installations One pipe installations must be absolutely air tight to prevent leaks or loss of p...

Page 10: ...mp Remove plug from return port Insert bypass plug Attach return and inlet lines Always terminate return line as shown in Figure 7 To determine two pipe maximum line lengths use Table 2 page 10 Figure...

Page 11: ...n servicing a NO HEAT call Check each item below making sure to complete each check before going to the next one Thermostat s Main fuse and power supply Service switch on boiler Oil level in oil tank...

Page 12: ...oil and spark but no flame Check for Loose dirty or defective nozzle Low pump pressure Excess air high draft Incorrect electrode settings Improper oil conditions Improper spinner position To verify p...

Page 13: ...for Defective motor bearings Pump and motor shaft mis aligned Defective ignitor Defective primary control If you hear combustion noise Check for Insufficient draft in breeching or overfire Impropermix...

Page 14: ...10 643 900 310 12 Nozzle adapter kit 643 900 005 13 Electrode assembly kit 643 900 010 14 Adjustment cam kit 643 900 325 643 900 326 15 Screw captive 8 32 x 3 8 12 per bag 643 900 085 16 Wire assembly...

Page 15: ...Part number 644 500 065 0200 15 QB 180 300 Oil Burners Series 2 Burner Manual 06510 18 16 19 20 21 17 22 15 14 13 12 11 1 2 3 4 5 5a QB180 5a QB300 7 8 9 10 23 6...

Page 16: ...ly by chemical vapors or with im proper fuel additives This warranty extends only to the first retail purchaser of the burner and only to a burner that has not been moved from its original installatio...