Part number 550-100-192/0917

3

STOP!! — Read before proceeding

®

 

gas

-

fired

 

water

 

boiler

 — 

70/110/155

 

User’s information Manual

 

Have this boiler serviced/inspected by 

a qualified service technician, at least 

annually.

 

Failure to comply with the above could result 

in severe personal injury, death or substantial 

property damage.

  When calling or writing about the boiler— 

Please have the boiler model number from 

the boiler rating label and the CP number 

from the boiler cabinet.

Should overheating of boiler occur or gas supply fail 
to shut off

DO NOT

 

turn off or disconnect electrical supply to 

circulator. Instead, shut off the gas supply at a location external to the 
appliance

.

 

If any part of a boiler, burner or its controls has 

been sprayed with or submerged under water, 

either partially or fully, DO NOT attempt to op-

erate the boiler until the boiler has been either 

replaced or completely repaired, inspected, 

and you are sure that the boiler and all compo-

nents are in good condition and fully reliable.

  

Otherwise, by operating this boiler, you will cause 
a fire or explosion hazard, and an electrical shock 
hazard, leading to serious injury, death, or substan-
tial property damage. See the instructions at right.

Saltwater Damage

 — The exposure of boiler components 

to saltwater can have both immediate and long-term effects. 
While the immediate effects of saltwater damage are similar 
to those of freshwater (shorting out of electrical compo-
nents, washing out of critical lubricants, etc.), the salt and 
other contaminants left behind can lead to longer term issues 
after the water is gone due to the conductive and corrosive 
nature of the salt residue. Therefore, Weil-McLain equip-
ment contaminated with saltwater or polluted water will no 
longer be covered under warranty and should be replaced.

Electrical Damage

 — If any 

electrical component

 or 

wiring

 

came into contact with water, or was suspected to have come 
into contact with water, do not use this boiler. Immediately call 
a qualified service technician to inspect the boiler and to replace 
any part of the control system and any gas control that has been 
in contact with water.

 

Failure to adhere to the guidelines on this page can result in severe per-

sonal injury, death or substantial property damage

.

Boiler service and maintenance —

•  To  avoid  electric  shock, 

interrupt electrical  

supply

 before performing maintenance.

•  To avoid severe burns, 

allow boiler to cool

 before 

performing maintenance.

•  You  must 

maintain

 the boiler as outlined in the 

manual and have the boiler 

started up and ser-

viced at least annually by a qualified service 

technician

 to ensure boiler/system reliability.

Boiler operation —

•  Do not block flow of combustion or ventilation air to 

boiler. This boiler is equipped with a control which will 

automatically shut down the boiler should air or vent be 

blocked. If vent or air blockage is easily accessible and 

removable, remove it. The boiler should attempt to restart 

within an hour. If blockage is not obvious or cannot be 

removed, have the boiler and system checked by a quali-

fied service technician.

Combustion air —

• 

DO NOT obstruct the combustion air intake or 

expose the air intake to corrosive chemicals 

(see next page).

Carbon monoxide detector —

•  A carbon monoxide detector that is wired on the same 

electrical circuit as the boiler is strongly recommended.

Boiler water —

•  Do not use petroleum-based cleaning or sealing compounds 

in boiler system. Gaskets and seals in the system may be dam-

aged. This can result in substantial property damage.

• 

Leaks in boiler or piping must be repaired at once 

to prevent make-up water. Use this boiler ONLY in 

a closed-loop system.

 Continual fresh make-up water 

will reduce boiler life. Mineral buildup in heat exchangers 

reduces heat transfer, overheats the materials, and causes 

failure. Addition of oxygen carried in by make-up water can 
cause internal corrosion. 

• 

Do not add cold water to hot boiler.

 Thermal 

shock can cause heat exchanger to crack.

Freeze protection fluids —

•  NEVER use automotive or standard glycol antifreeze. Use 

only freeze-protection fluids made for hydronic systems. 

Follow all guidelines given by the antifreeze manufacturer. 

Thoroughly clean and flush any replacement boiler system 

that has used glycol before installing the new boiler. Use only 

the products listed by Weil-McLain for use with this boiler. 

See boiler manual for details.

 

Frozen Water Damage Hazard

Residences or buildings that are unattended in severely cold 

weather, boiler system components failures, power outages, or 

other electrical system failures could result in frozen plumbing 

and water damage in a matter of hours. For your protection, take 

preventative actions such as having a security system installed 

that operates during power outages, senses low temperature, 

and initiates an effective action. Consult with your boiler con-

tractor or a home security agency.

Summary of Contents for Evergreen 110

Page 1: ...or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any te...

Page 2: ...onal injury death or substantial property damage Indicates presence of hazards that can cause severe personal injury death or substantial property damage Indicates presence of hazards that will or can...

Page 3: ...cal supply before performing maintenance To avoid severe burns allow boiler to cool before performing maintenance You must maintain the boiler as outlined in the manual and have the boiler started up...

Page 4: ...dirt Areas likely to have contaminants Dry cleaning laundry areas and establishments Swimming pools Metal fabrication plants Beauty shops Refrigeration repair shops Photo processing plants Auto body s...

Page 5: ...Check air openings Check pressure temperature gauge Verify boiler jacket door is securely closed MONTHLY Check vent piping Check air piping Check relief valve Check condensate drain system Check autom...

Page 6: ...auge 1 Make sure the pressure reading on the boiler pressure temperaturegaugedoesnotexceed 24 psig Higher pressure may indicate a problem with the expansion tank 2 Contact a qualified service technici...

Page 7: ...e tube is in good condition and that condensate can run freely 2 Inspect the boiler condensate trap located under the boiler see Figure 3 Make sure the ball float in the trap is in place and appears t...

Page 8: ...n system to refer to after checking relief valve 3 Lift the relief valve top lever slightly allow ing water to relieve through the valve and discharge piping 4 If water flows freely release the lever...

Page 9: ...Part number 550 100 192 0917 9 Figure 5 Operating instructions see page 2 for location of manual gas valve gas fired water boiler 70 110 155 User s information Manual OPERATING INSTRUCTIONS...

Page 10: ...ate also flashes fault name during lockout Active system type Outdoor air temperature Setpoint temperature or percentage if shadow Boiler out or system sensor depending upon settings Firing Rate Input...

Page 11: ...M A N D 1 2 3 N E X T EVG 001 bs 2 H H M M A M M M D D Y Y S T A T U S O U T D O O R T E M P F T A R G E T T E M P F B O I L E R T E M P F M O D U L A T I O N I N P U T S T A T U S 0 1 0 V 1 D H W S...

Page 12: ...12 gas fired water boiler 70 110 155 User s information Manual...