Boiler Manual
Category
E2 prom parameters
Unit
Range
Def
Description
Num.
Address
Description
Low
High
Value
Flame current supervi-
sion
142
ML – 80D5
Flame current on level1 offset
ADC
0
255
3
Flame current supervi-
sion
143
ML – 80DB
Flame current on level2 offset
ADC
0
255
0
Flame current supervi-
sion
144
ML – 8112
Flame current off level offset
ADC
0
255
20
System
145
ML – 8134
High altitude & Chimney length selection
Num
0
2
0
System
146
ML – 8131
Pre-purge time between A01 attempts
Min
0
60
0
System
147
ML – 80D6
Pump protection time
Sec
0
20
5
Fan Regulation
148
CL5 – 0AC8
FAN Kp Up
Num
0
100
25
Fan Regulation
149
CL5 – 0AF4
FAN Ki Up
Num
0
255
220
Fan Regulation
150
CL5 – 1B8C
FAN Kp Down
Num
0
100
25
Fan Regulation
151
CL5 – 1BB0
FAN Ki Down
Num
0
255
250
Heat exchanger pro-
tection
152
ML – 80DD
Heat exchanger protection
°F/Sec
0
27
18
]{!|
153,2
ML – 80D2
Priority Over Ride Set
°F
0
240
30
]{!|
154,2
ML – 80D3
Priority Over Ride Reset
°F
0
240
15
]{!
155,1
ML – 810F
Short tapping
Sec
0
255
30
]{!
156,1
ML – 80DF
Peak pump on fan speed
Hz
0
255
120
]{!
157,1
ML – 80D8
Peak pump switch on time
Sec
0
255
20
]{!
158,1
ML – 80CD
Peak remove time
Sec
0
20
0
]{!
159,1
ML – 80CE
Peak remove switch off temperature
°F
32
212
194
]{!
160,1
ML – 80CF
Peak pump speed
%
0
100
100
System
161
ML – 80D7
Fan type selection
Num
0
1
1
System
162
ML - 8121
High limit protection timer
Sec
0
20
10
System
163
ML – 80D4
OTC Exempt
Num
0
1
0
]{!
164,1
ML – 80DA
DHW Comfort pump on time
Sec
0
30
2
Chimney material
165
ML – 8110
PVC/CPVC Selection
Num
0
2
1
Chimney material
166
ML – 8132
PVC maximum temperature
°F
140
212
190
Chimney material
167
ML – 8133
CPVC maximum temperature
°F
158
230
200
Wind condition
168
ML - 8135
Wind condition time
Sec
0
60
10
Wind condition
169
ML - 8136
Wind condition frequency
Hz
0
255
110
Wind condition
170
ML - 8137
Wind condition ADC
ADC
0
255
30
]{!|
171,2
ML – 8111
DHW thermostat/sensor selection
Num
0
1
0
]{!|
172,2
ML – 80C7
DHW tank prepare mode
Num
0
2
0
]{!|
173,2
ML – 80D1
DHW Delta
°F
0
35
18
]{!|
174,2
ML – 80CC
DHW slope control
°F/min
1
20
9
]{!
172,4
ML – 80C7
DHW tank prepare mode
Num
0
2
0
]{!
173,4
ML – 80D1
DHW Delta
°F
0
35
18
]{!
174,4
ML – 80CC
DHW slope control
°F/min
1
20
9
]{!|
175,2
ML – 813F
"`Q\]{!`"^\]
Num
0
1
0
Flame current supervi-
sion
176
CL5 – AAA1
#X^$"ZX`X]^Q;Q\Z\^
Num
1
20
20