![Weidmüller 1500440000 Operating And Maintenance Instruction Manual Download Page 33](http://html1.mh-extra.com/html/weidmuller/1500440000/1500440000_operating-and-maintenance-instruction-manual_952274033.webp)
Troubleshooting
1548650000/00/06.14
33
6.
Troubleshooting
Fault
Cause
Corrective measure
Flash is formed on the
connection fittings.
•
A cross sectional area has
been set too small.
•
Set the correct cross
section.
•
An unsuitable cable lug or
connector is being used.
•
Change the cable lug /
connector to be proc-
essed.
•
Change the crimping
tool.
•
None of the above reasons
•
Consult the manufac-
turer, the crimping tool
must be checked
The connection is not
pressed hard enough /
the cable can be de-
tached from the con-
nector after process-
ing.
•
A cross sectional area has
been set too large.
•
Set the correct cross
section.
•
An unsuitable cable lug or
connector is being used.
•
Change the cable lug /
connector to be proc-
essed
•
Change the crimping
tool.
•
None of the above reasons
•
Consult the manufac-
turer, the crimping tool
must be checked.
The crimping insert
cannot be moved.
•
The locking bolt is en-
gaged
•
Push the locking pin in
The crimping insert is
difficult to adjust with
the locking pin pushed
in.
•
Tool is dirty.
•
Clean tool
•
Tool is insufficiently
greased
•
Apply grease to the tool
If the fault still occurs, con-
sult the manufacturer.
Crimping tool must be
checked.