Maintenance
69
5.4.2 Engine Start-up after Long-term Storage
Drain the residual 30/M protective oil from the sump.
Add the type and quantity of lubricant oil to the engine as specified in the
REFILLING
table.
Drain the protective fluid CFB from the gas circuit bringing to close the operations as
indicated in point 4 of the
PREPARATIONOF THE ENGINE FOR A LONG PERIOD OF
INACTIVITY.
Remove the plugs and/or seals from the engine's intake, discharge, ventilation, and
bleeder holes, and restoring normal conditions of use. Connect the turbocharger intake
inlet to the air filter.
Join the gas circuits to the machine's tank bringing it close the operation as indicated in
point 4 of the
5.4.1
. During the filling operations, connect the tank gas return line to a
collection container to prevent the residual protective liquid from flowing into the tank.
Check and fill the engine with coolant as required, degassing if necessary.
Start the engine and let it idle until completely stabilized.
Check that the indications on the dashboard are suitable and that there are no alarm
signals.
Stop the engine.
Remove the warning notices of
ENGINE WITHOUT OIL
from the engine and dashboard.