7�2
Installing the filter
Please note:
Subsequent mentions of descriptions and position numbers refer to
Chapter 3. Product overview / product description on page 11
Î
Install the WEH
®
Product so that the plug (Pos. 210) for
the drain port “Q” is pointing perpendicularly down and is
easily accessible. The plug must be unscrewed to allow
accumulated oil to be bled off.
Attention:
Please note the flow direction marked
).
Î
Unscrew the protection caps from the ports.
Î
Use an open-ended wrench to hold the wrench flats in
place when installing the WEH
®
Product.
Î
Screw the media inlet ‘B1’ of the filter housing pressure-tight to the media inlet.
For the tightening torque, please refer to the table below.
Attention:
Please note the flow direction marked on the product.
Note:
For tube fittings, please note the WEH
®
Operating instructions "Products with
double ferrule fitting".
Î
Screw the media outlet ‘B2’ of the filter housing pressure-tight to the media outlet.
For the tightening torque, please refer to the table below.
Attention:
Please note the flow direction marked on the product.
Note:
For tube fittings, please note the WEH
®
Operating instructions "Products with
double ferrule fitting".
Ports
Torque
UNF 9/16"-18
35 Nm +10%
UNF 3/4"-16
70 Nm +10%
Î
Please note the connection size marked on your product.
- Other connection sizes are available on request.
- Optionally, the WEH
®
Product can be attached at any posi-
tion via the 4 bores. Fasten the coalescing filter as shown
in the bore hole image (
).
Figure 1
32
(16)
(16)
32
(16)
(16)
M8
depth 15 mm
>>>
Figure 2
MD-10029-L51-R2.1.0-03