Wegener Nielsen NAVE IIc Quick Start Manual Download Page 4

NAVE

 

II

Q

UICK 

S

TART 

G

UIDE

 

 

 

800026-02 Rev. A 

4

 

www.wegener.com

 

NOTE:

 The 

Encoder

 must be configured with an 

IP address

 before the 

Web 

Interface

 can be used. See below for information on configuring the 

NAVE IIc Encoder

’s IP address, or see 

Appendix A

 for configuring the 

PC network settings to work with the default 

NAVE IIc

 settings. 

8.

 

IP Configuration Setup for Web Browser Control

 

The 

default

 setting for the 

NAVE IIc Encoder

’s 

Network

 port is 

Static Mode

with an 

IP address

 of 

10.61.62.63

 and a 

Subnet mask

 of 

255.255.255.0

.  

NOTE:

  Consult your Network Administrator to determine whether these 

defaults can be used on the network where you will install the 

NAVE 

IIc Encoder

. You may need to configure it for 

DHCP Mode

, to use a 

different 

Static IP address

, or to change the 

Subnet Mask

 or 

Gateway 

Addresses

 (as described in the following steps).

 

a. 

From the 

Home

 screen

 on the Front Panel LCD screen, press the right arrow 

Z

 

button until the LCD shows 

SYSTEM CONFIGURATION

.

 

b. 

Press the 

ENTER/ POWER

 button to set the System Configuration. (Using the 

Y

 and

 

Z

 

arrow

 

buttons will move you to the other top-level menu screens.)

 

c. 

When the LCD screen shows 

IP CONFIGURATION SELECT?

 press 

ENTER/ 

POWER

 again.

 

d. 

The next LCD screen displays 

IP SETTINGS STATIC

 on the top line, while the 

second line scrolls through the default IP configuration settings. Pressing 

ENTER/ POWER

 at any time on this screen will drop you down into the 

IP 

Setup

 menus. 

 

e. 

The first 

IP Setup

 screen is 

IP

 

ADDRESS

 

MODE

. Pressing the 

ENTER/ 

POWER

 button here allows you to select either 

STATIC

 or the 

DHCP

 IP 

Address Mode. 

 

f. 

If you select 

DHCP

, the 

NAVE IIc Encoder

 will request an IP address from 

your 

DHCP server

. The LCD screen will display the message, 

APPLYING IP 

SETTINGS PLEASE WAIT…

, and then display the new DHCP-assigned IP 

address. 

 

g. 

If you need a 

Static

 IP address, but a different 

IP address

 or 

Subnet Mask

 

than the default settings, then use 

Z

 to move one screen to the right until you 

see the screen with 

IP ADDRESS

 with the default address below it.

 

NOTE:

  For IP addresses that include subfields with leading zeros, you must 

enter those zeros when entering the address in the 

NAVE IIc

. For 

example, 

IP address 128.92.56.4

 would be entered as 

128.092.056.004

.

 

h. 

Press 

ENTER/ POWER

 to edit the default address.

 

(See 

Menu Navigation

 

on page 2 to change editable data.) After entering the new IP address, 
press the 

ENTER/POWER

 button.

 

i. 

The LCD screen will display the message, 

APPLYING IP SETTINGS 

PLEASE WAIT..,

 and then display the 

SUBNET ADDRESS 

screen with the 

default mask address.

 

j. 

Press 

ENTER/ POWER

 to modify the 

Subnet address

 (if needed). (and 

then the Gateway address, if needed). 

 

k. 

Record the new 

IP Address

 of the 

NAVE IIc 

unit displayed on the LCD 

screen.

 

l. 

Using a computer on the network attached to the 

NAVE IIc

, open your 

web browser.

 

m. 

Type the 

IP Address

 noted from the 

IP Address

 screen in the browser's 

address box. Leading zeros must be omitted when entering IP address 
on Web browser.

 

n. 

Press <

Enter

> (on the computer keyboard) and the 

NAVE IIc

's 

Status

 

page will be displayed (

Figure 4

).

 

Figure 4: 

NAVE IIc Web Interface Status Page 

 

o. 

To see detailed information about the transport stream, click the 

Stream Info

 tab (

Figure 5

 on the next page). Information from this tab is 

required to configure the 

SID Assignment

 tab.

 

NOTE:

  When the Front Panel 

Forced Bypass

 Switch is illuminated, no stream 

information will be displayed on the 

Stream Info

 page.  

9.  Assigning Nielsen Source IDs (SIDs) 

Each SID must be assigned to a 

Major/Minor Channel Number

,

 a 

Program 

Number

, or to an 

Audio PID Number

. Click the 

SID Assignment

 tab to begin 

(

Figure 6

 on the next page). 

Summary of Contents for Nielsen NAVE IIc

Page 1: ... com 1 Remove the NAVE IIc ac power cord and CD ROM Manual from the shipping carton Call your shipping carrier immediately if any damage is discovered 2 Remove the clear plastic covering from around the bottom of the unit and over the LCD window on the front panel 3 Place the NAVE IIc indoors on a well supported flat table or desktop or mount it in a standard equipment rack If rack mounting your N...

Page 2: ...l a The Liquid Crystal Display LCD provides menu data and input screens to the user Menu screens are entry points to additional screens These may be data screens that display signal or unit status information or input screens where settings can be changed by the user b The NAVE IIc s Home screen displays the unit s input output stream type ASI or SMPTE310M the TSID number in hex as read from the i...

Page 3: ...d Constant A warning has been issued recently See error log for details Warning Yellow Off No current Warning condition exists Table 1 Front Panel LED Indicator Descriptions Continued LED Label LED Color LED STATE Meaning Constant An error has occurred See error log for details Alarm Red Off No current Alarm condition exists Constant The encoder is in firmware bypass mode System Bypass Red Off No ...

Page 4: ...essage APPLYING IP SETTINGS PLEASE WAIT and then display the new DHCP assigned IP address g If you need a Static IP address but a different IP address or Subnet Mask than the default settings then use Z to move one screen to the right until you see the screen with IP ADDRESS with the default address below it NOTE For IP addresses that include subfields with leading zeros you must enter those zeros...

Page 5: ... entered as capital letters If your transmission has more than one program in it you must assign the correct SID for the correct program content NOTE The Nielsen Encoder Support Group will supply this information to you b Next select how you want to assign the SID you can choose Major Minor Program Number or Audio PID from a drop down selection box c Depending on the Selection Mode chosen in Step ...

Page 6: ...asswords Page Name User Name Password SID Assignment config config Configuration config config Service service service The Service User Name and Password provide access to all password protected pages Users with config privileges have access to the SID Assignment and Configuration pages which handle the normal unit and data stream configuration processes 11 Completing the NAVE IIc Encoder Configur...

Page 7: ...eral purpose input 3 General purpose input 4 General purpose input 5 General purpose input 6 User Relay N C contact User Relay COM contact User Relay N O contact GND Alarm N O contact OK COM closes here when unit OK Alarm COM contact Alarm N C contact Alarm COM closes here on alarm or if power is off GND Table 5 NAVE IIc Encoder Interconnect Descriptions Continued Connector Label Connector Type Pi...

Page 8: ... Network window in order to install the adapter TCP IP or Client for Microsoft Networks A 2 2 If you need the Ethernet Network Adapter a Click Add b Select Adapter then click Add again c Select the manufacturer and model of your Ethernet adapter and click OK A 2 3 If you need TCP IP a Click Add b Select Protocol then click Add again c Select Microsoft d Select TCP IP and click OK A 2 4 If you need...

Page 9: ...sh to configure Select Properties e The LAN Properties dialog window appears A 4 2 Setting the Encoder s TCP IP Address a Select Internet Protocol TCP IP b Click Properties The Internet Protocol Properties dialog window appears c Select the Use the following IP address radio button d Enter the static IP address 10 61 62 62 in the first field e Enter the Subnet Mask 255 255 255 0 in the second fiel...

Page 10: ...riod of one year after shipment to customer WEGENER s obligation under this warranty is limited to repairing or at WEGENER s option replacing parts subassemblies or entire assemblies WEGENER shall not be liable for any special indirect or consequential damages This warranty does not cover parts or equipment which have been subject to misuse negligence or accident by the customer during use All shi...

Reviews: