![Wegener Nielsen NAVE IIc Quick Start Manual Download Page 4](http://html1.mh-extra.com/html/wegener/nielsen-nave-iic/nielsen-nave-iic_quick-start-manual_950845004.webp)
NAVE
II
C
Q
UICK
S
TART
G
UIDE
800026-02 Rev. A
4
www.wegener.com
NOTE:
The
Encoder
must be configured with an
IP address
before the
Web
Interface
can be used. See below for information on configuring the
NAVE IIc Encoder
’s IP address, or see
Appendix A
for configuring the
PC network settings to work with the default
NAVE IIc
settings.
8.
IP Configuration Setup for Web Browser Control
The
default
setting for the
NAVE IIc Encoder
’s
Network
port is
Static Mode
,
with an
IP address
of
10.61.62.63
and a
Subnet mask
of
255.255.255.0
.
NOTE:
Consult your Network Administrator to determine whether these
defaults can be used on the network where you will install the
NAVE
IIc Encoder
. You may need to configure it for
DHCP Mode
, to use a
different
Static IP address
, or to change the
Subnet Mask
or
Gateway
Addresses
(as described in the following steps).
a.
From the
Home
screen
on the Front Panel LCD screen, press the right arrow
Z
button until the LCD shows
SYSTEM CONFIGURATION
.
b.
Press the
ENTER/ POWER
button to set the System Configuration. (Using the
Y
and
Z
arrow
buttons will move you to the other top-level menu screens.)
c.
When the LCD screen shows
IP CONFIGURATION SELECT?
press
ENTER/
POWER
again.
d.
The next LCD screen displays
IP SETTINGS STATIC
on the top line, while the
second line scrolls through the default IP configuration settings. Pressing
ENTER/ POWER
at any time on this screen will drop you down into the
IP
Setup
menus.
e.
The first
IP Setup
screen is
IP
ADDRESS
MODE
. Pressing the
ENTER/
POWER
button here allows you to select either
STATIC
or the
DHCP
IP
Address Mode.
f.
If you select
DHCP
, the
NAVE IIc Encoder
will request an IP address from
your
DHCP server
. The LCD screen will display the message,
APPLYING IP
SETTINGS PLEASE WAIT…
, and then display the new DHCP-assigned IP
address.
g.
If you need a
Static
IP address, but a different
IP address
or
Subnet Mask
than the default settings, then use
Z
to move one screen to the right until you
see the screen with
IP ADDRESS
with the default address below it.
NOTE:
For IP addresses that include subfields with leading zeros, you must
enter those zeros when entering the address in the
NAVE IIc
. For
example,
IP address 128.92.56.4
would be entered as
128.092.056.004
.
h.
Press
ENTER/ POWER
to edit the default address.
(See
Menu Navigation
on page 2 to change editable data.) After entering the new IP address,
press the
ENTER/POWER
button.
i.
The LCD screen will display the message,
APPLYING IP SETTINGS
PLEASE WAIT..,
and then display the
SUBNET ADDRESS
screen with the
default mask address.
j.
Press
ENTER/ POWER
to modify the
Subnet address
(if needed). (and
then the Gateway address, if needed).
k.
Record the new
IP Address
of the
NAVE IIc
unit displayed on the LCD
screen.
l.
Using a computer on the network attached to the
NAVE IIc
, open your
web browser.
m.
Type the
IP Address
noted from the
IP Address
screen in the browser's
address box. Leading zeros must be omitted when entering IP address
on Web browser.
n.
Press <
Enter
> (on the computer keyboard) and the
NAVE IIc
's
Status
page will be displayed (
Figure 4
).
Figure 4:
NAVE IIc Web Interface Status Page
o.
To see detailed information about the transport stream, click the
Stream Info
tab (
Figure 5
on the next page). Information from this tab is
required to configure the
SID Assignment
tab.
NOTE:
When the Front Panel
Forced Bypass
Switch is illuminated, no stream
information will be displayed on the
Stream Info
page.
9. Assigning Nielsen Source IDs (SIDs)
Each SID must be assigned to a
Major/Minor Channel Number
,
a
Program
Number
, or to an
Audio PID Number
. Click the
SID Assignment
tab to begin
(
Figure 6
on the next page).