Figure 3:
LCD Front Panel Menu Summary
d.
Ten Front Panel light-emitting diodes (LEDs) illuminate to show unit
status at a glance.
Table 1
gives the meaning of each LED indicator.
Please refer to
Table 2
for the meaning of the rear panel Transport I/O
card LED indicators.
Table 1. Front Panel LED Indicator Descriptions
LED
Label
LED
Color
LED
S
TATE
Meaning
Constant The receiver is enabled and the unit is receiving a valid
transport stream.
Rx
Green
Off
Valid data has not been received for 0.1 seconds
Constant The transmitter is enabled and data is being transmitted.
Tx
Green
Off
Valid data has not been sent for 0.1 seconds
Constant The watermarking process has started, and no alarms are
present
System
Green
Off
The NAVE IIc Watermark function is shut down, but the
Encoder is monitoring the stream.
Constant The encoder has inserted at least one SID in the last second
or two
Encode
Green
Off
The NAVE IIc encoder is not watermarking the AC3 audio
frames
Constant The encoder is receiving PSIP packets, and the Program
information in the PSIP packet matches the PMT and PAT
PSIP
Green
Off
No PSIP information can be found in the stream, or the PSIP
information is incorrect
Constant The modem is on and in use
Modem
Green
Off
No modem activity is detected
Constant A warning has been issued recently. See error log for details.
Warning
Yellow
Off
No current Warning condition exists
Table 1. Front Panel LED Indicator Descriptions
(Continued)
LED
Label
LED
Color
LED
S
TATE
Meaning
Constant An error has occurred. See error log for details.
Alarm
Red
Off
No current Alarm condition exists
Constant The encoder is in firmware-bypass mode.
System
Bypass
Red
Off
No critical error is occurring.
Constant The
Forced Bypass
switch will be illuminated
Red
when the
switch is pressed in (engaged). In this position all transport
stream processing and monitoring stops, until the switch is
disengaged.
Forced
Bypass
(Switch
CAP)
Red
Off
The Forced Bypass switch is not engaged.
Table 2 Rear Panel Transport I/O Card LED Indicator Descriptions
LED
Label
LED
Color
LED
State
Meaning
Flashes
The receiver is enabled and the unit is receiving a valid
transport stream.
Rx
Red
Off
Valid data has not been received for 0.1 seconds
Off
No Carrier is detected on the Receive input
CD
Red
Constant A carrier is detected on the receive BNC input.
Flashes
The transmitter is enabled and data is being transmitted.
Tx
Green
Off
Valid data has not been sent for 0.1 seconds
Off
Synchronization can not be detected on Receive BNC input
SYNC
Green
Constant The received input stream is packet synchronized
e.
The
Web Interface
for the
NAVE IIc Encoder
enables you to control and
view the state of the
Encoder
remotely via a web browser on a PC. It
mirrors the functionality of the
Encoder
's front panel interface.