Wegener Nielsen NAVE IIc Quick Start Manual Download Page 3

 

 

NAVE

 

II

Q

UICK 

S

TART 

G

UIDE

 

www.wegener.com

 

3

 

800026-02 Rev. A

 

Figure 3: 

LCD Front Panel Menu Summary 

d. 

Ten Front Panel light-emitting diodes (LEDs) illuminate to show unit 
status at a glance. 

Table 1

 gives the meaning of each LED indicator. 

Please refer to 

Table 2

 for the meaning of the rear panel Transport I/O 

card LED indicators.

 

Table 1.  Front Panel LED Indicator Descriptions 

LED  

Label 

LED 

Color  

LED

 

 

S

TATE

 

 

Meaning 

Constant  The receiver is enabled and the unit is receiving a valid  

transport stream.  

Rx 

Green  

Off 

Valid data has not been received for 0.1 seconds 

Constant  The transmitter is enabled and data is being transmitted. 

Tx 

Green 

Off 

Valid data has not been sent for 0.1 seconds 

Constant  The watermarking process has started, and no alarms are 

present 

System 

Green  

Off 

The NAVE IIc Watermark function is shut down, but the 
Encoder is monitoring the stream. 

Constant  The encoder has inserted at least one SID in the last second 

or two 

Encode 

Green  

Off 

The NAVE IIc encoder is not watermarking the AC3 audio 
frames 

Constant  The encoder is receiving PSIP packets, and the Program 

information in the PSIP packet matches the PMT and PAT 

PSIP 

Green 

Off 

No PSIP information can be found in the stream, or the PSIP 
information is incorrect 

Constant  The modem is on and in use 

Modem 

Green  

Off 

No modem activity is detected 

Constant  A warning has been issued recently. See error log for details. 

Warning 

Yellow  

Off 

No current Warning condition exists 

Table 1.  Front Panel LED Indicator Descriptions

 (Continued) 

LED 

Label 

LED 

Color  

LED

 

 

S

TATE

 

 

Meaning 

Constant  An error has occurred. See error log for details. 

Alarm 

Red  

Off 

No current Alarm condition exists 

Constant  The encoder is in firmware-bypass mode. 

System 
Bypass 

Red 

Off 

No critical error is occurring. 

Constant  The 

Forced Bypass 

switch will be illuminated 

Red

 when the 

switch is pressed in (engaged). In this position all transport 
stream processing and monitoring stops, until the switch is 
disengaged. 

Forced 
Bypass 

(Switch 
CAP)

 

Red  

Off 

The Forced Bypass switch is not engaged. 

Table 2 Rear Panel Transport I/O Card LED Indicator Descriptions 

LED 

Label 

LED 

Color 

LED 

State 

 

Meaning 

Flashes 

The receiver is enabled and the unit is receiving a valid 
transport stream. 

Rx 

Red 

Off 

Valid data has not been received for 0.1 seconds 

Off 

No Carrier is detected on the Receive input 

CD 

Red 

Constant A carrier is detected on the receive BNC input. 
Flashes 

The transmitter is enabled and data is being transmitted. 

Tx 

Green 

Off 

Valid data has not been sent for 0.1 seconds 

Off 

Synchronization can not be detected on Receive BNC input 

SYNC 

Green 

Constant The received input stream is packet synchronized

 

e. 

The 

Web Interface

 for the 

NAVE IIc Encoder

 enables you to control and 

view the state of the 

Encoder

 remotely via a web browser on a PC. It 

mirrors the functionality of the 

Encoder

's front panel interface.

 

Summary of Contents for Nielsen NAVE IIc

Page 1: ... com 1 Remove the NAVE IIc ac power cord and CD ROM Manual from the shipping carton Call your shipping carrier immediately if any damage is discovered 2 Remove the clear plastic covering from around the bottom of the unit and over the LCD window on the front panel 3 Place the NAVE IIc indoors on a well supported flat table or desktop or mount it in a standard equipment rack If rack mounting your N...

Page 2: ...l a The Liquid Crystal Display LCD provides menu data and input screens to the user Menu screens are entry points to additional screens These may be data screens that display signal or unit status information or input screens where settings can be changed by the user b The NAVE IIc s Home screen displays the unit s input output stream type ASI or SMPTE310M the TSID number in hex as read from the i...

Page 3: ...d Constant A warning has been issued recently See error log for details Warning Yellow Off No current Warning condition exists Table 1 Front Panel LED Indicator Descriptions Continued LED Label LED Color LED STATE Meaning Constant An error has occurred See error log for details Alarm Red Off No current Alarm condition exists Constant The encoder is in firmware bypass mode System Bypass Red Off No ...

Page 4: ...essage APPLYING IP SETTINGS PLEASE WAIT and then display the new DHCP assigned IP address g If you need a Static IP address but a different IP address or Subnet Mask than the default settings then use Z to move one screen to the right until you see the screen with IP ADDRESS with the default address below it NOTE For IP addresses that include subfields with leading zeros you must enter those zeros...

Page 5: ... entered as capital letters If your transmission has more than one program in it you must assign the correct SID for the correct program content NOTE The Nielsen Encoder Support Group will supply this information to you b Next select how you want to assign the SID you can choose Major Minor Program Number or Audio PID from a drop down selection box c Depending on the Selection Mode chosen in Step ...

Page 6: ...asswords Page Name User Name Password SID Assignment config config Configuration config config Service service service The Service User Name and Password provide access to all password protected pages Users with config privileges have access to the SID Assignment and Configuration pages which handle the normal unit and data stream configuration processes 11 Completing the NAVE IIc Encoder Configur...

Page 7: ...eral purpose input 3 General purpose input 4 General purpose input 5 General purpose input 6 User Relay N C contact User Relay COM contact User Relay N O contact GND Alarm N O contact OK COM closes here when unit OK Alarm COM contact Alarm N C contact Alarm COM closes here on alarm or if power is off GND Table 5 NAVE IIc Encoder Interconnect Descriptions Continued Connector Label Connector Type Pi...

Page 8: ... Network window in order to install the adapter TCP IP or Client for Microsoft Networks A 2 2 If you need the Ethernet Network Adapter a Click Add b Select Adapter then click Add again c Select the manufacturer and model of your Ethernet adapter and click OK A 2 3 If you need TCP IP a Click Add b Select Protocol then click Add again c Select Microsoft d Select TCP IP and click OK A 2 4 If you need...

Page 9: ...sh to configure Select Properties e The LAN Properties dialog window appears A 4 2 Setting the Encoder s TCP IP Address a Select Internet Protocol TCP IP b Click Properties The Internet Protocol Properties dialog window appears c Select the Use the following IP address radio button d Enter the static IP address 10 61 62 62 in the first field e Enter the Subnet Mask 255 255 255 0 in the second fiel...

Page 10: ...riod of one year after shipment to customer WEGENER s obligation under this warranty is limited to repairing or at WEGENER s option replacing parts subassemblies or entire assemblies WEGENER shall not be liable for any special indirect or consequential damages This warranty does not cover parts or equipment which have been subject to misuse negligence or accident by the customer during use All shi...

Reviews: