![WEG SCW100 Series User Manual Download Page 8](http://html.mh-extra.com/html/weg/scw100-series/scw100-series_user-manual_950607008.webp)
INTERFACE DESCRIPTION
2 INTERFACE DESCRIPTION
2.1 CHARACTERISTICS OF THE CAN INTERFACE
Interface galvanically insulated and with differential signal, providing more robustness against electromagnetic
interference.
External power supply of 24 V.
It allows the device to operate as CANopen slave.
Allows data communication for equipment operation and parameterization.
Enables communication using baud rates from 20 Kbits/s up to 1 Mbit/s.
Maximum bus length of 1000 meters.
LED Net
CAN Connector (CANopen)
S1
S2
Address
S3: Baud
S4: Termination
Figure 2.1:
Connector, indications and configurations for SCW100
2.2 CONNECTOR
The interface is available through a 4-wire plug-in connector with the following pin assignment:
5
8
Table 2.1:
Pin assignment of connector for CANopen interface
Pin
Name
Function
5
CAN_H
Communication signal CAN_H
6
Shield
Cable shield
7
CAN_L
Communication signal CAN_L
8
CAN_GND
0V for CAN insulated interface circuit
2.3 ADDRESS
The product address is configured using two hex keys S1 and S2 as illustrated in the figure 2.2.
SCW100 | 8