5
DETAILED PARAMETER DESCRIPTION
Table 5.45:
Digital and relay output functions
hhhhhhh
hhhhh
Function
DOx Parameter
(DO1)
(DO2)
(RL1)
(RL2)
(RL3)
(RL4)
(RL5)
Not Used
0, 8,
9, 23
and 29
0, 8,
9, 23
and 29
0, 8,
9, 23
and 29
0, 8, 9
and 23
0, 8, 9
and 23
0, 8,
9, 23
and 29
0, 8, 9,
and 29
N* > Nx
1
1
1
1
1
1
1
N > Nx
2
2
2
2
2
2
2
N < Ny
3
3
3
3
3
3
3
N = N*
4
4
4
4
4
4
4
N = 0
5
5
5
5
5
5
5
Is > Ix
6
6
6
6
6
6
6
Is < Ix
7
7
7
7
7
7
7
Remote
10
10
10
10
10
10
10
Run
11
11
11
11
11
11
11
Ready
12
12
12
12
12
12
12
No Fault
13
13
13
13
13
13
13
14
14
14
14
14
14
14
No F0072
17
17
17
17
17
17
17
4 to 20 mA OK
18
18
18
18
18
18
18
Fieldbus
19
19
19
19
19
19
19
Forward
20
20
20
20
20
20
20
Process variable >VPx
21
21
21
21
21
21
21
Process variable <VPy
22
22
22
22
22
22
22
Pre-charge OK
24
24
24
24
24
24
24
Fault
25
25
25
25
25
25
25
N > Nx and Nt > Nx
26
26
26
26
26
26
26
Without Fault with delay
27
27
27
27
27
27
27
No Alarm
28
28
28
28
28
28
28
Timer
-
-
-
29
29
-
-
Redundant ventilation
30
30
30
30
30
30
30
PLC
-
-
31
31
31
-
-
Circuit Break ON (Input Circuit Breaker ON)
32
32
32
32
32
32
32
Transference OK
33
33
33
33
33
33
33
Synchronism OK
34
34
34
34
34
34
34
Serial
35
35
35
35
35
35
35
a) N > Nx
b) N < Nx
ON
OFF
OFF
N*
Nx (P0288)
N
Relay/
Transistor
Time
Time
OFF
ON
ON
N*
Ny (P0289)
N
Relay/
Transistor
Time
Time
c) N = N*
d) Is > Ix
ON
OFF
OFF
Relay/
Transistor
Time
Time
N*
N
ON
OFF
Ix (P0290)
Is
Relay/
Transistor
OFF
Time
Time
MVW3000 | 5-62