5
CONNECTING A DEVICE TO THE DRIVE SCAN
Table 5.20:
Parameters related to the SRW01 Ethernet Modbus protocol
Parameter
Description
Values range
P766
Gateway 1
0... 255
P767
Gateway 2
0... 255
P768
Gateway 3
0... 255
P769
Gateway 4
0... 255
P756
Modbus
TCP
timeout
0 a 999,9s
5.7.2
POSSIBLE FORMS OF CONNECTIONS
Figure 5.10
llustrates the possible ways to connect the SRW01 to the Drive Scan.
Motion Fleet Mangement
Cloud
Drive Scan
Ethernet network
Modbus-TCP protocol
SRW01 - Modbus TCP
SRW01 - Ethernet/IP
SRW01 - Pro
fi
netIO
Slave 1
Slave 2
Slave 20
Master
CLP
Figure 5.10:
Possible connections to the SRW01
WARNING!
The Drive Scan can only be connected to the internet using the Ethernet port GbE0 if it does not
have a proxy.
5.7.3
MONITORING
The Drive Scan continuously monitors the SRW01 parameters specified in
Section 5.7.3.1 Attributes Cyclically
Monitored by the SRW01 on page 5-26
.
After a cycle of all these readings, as well as of the other assets connected to the Drive Scan, a new reading cycle
starts automatically.
The parameters read are transformed into attributes, which can be:
Only at initialization;
Last value read;
Average value;
Minimum value;
Maximum value.
Every 5 minutes, the Drive Scan publishes the attributes to the WEG Motion Fleet Management platform.
In case of an internet connection failure, the Drive Scan stores the data for up to 30 days in the internal memory,
publishing it to the MFM when the connection is reestablished.
Low Voltage Devices | 5-25