Installation and Connection
Mount the inverter in the upright position on a flat and horizontal surface:
Figure 3.2:
Mechanical installation data
ATTENTION!
Provide for the physical separation of signal, control and power cables.
3.2 ELECTRICAL INSTALLATION
DANGER!
The following information is merely a guide for proper installation. Comply with
applicable local regulations for electrical installations.
Make sure the AC power supply is disconnected before starting the installation.
The ADW300 must not be used as an emergency stop device. Provide other
devices for that purpose.
3.2.1 Identification of the Power Terminals and Grounding Points
The location of the power, grounding and control connections are shown in
DANGER!
Before energizing the ADW300, check that the product power supply selector
switch is in the correct position, 110 V or 220 V.
Description of the power terminals:
L/L1, N/L2:
power supply connection (use the 6.3 mm Faston Tab for connection).
U, V and W:
connection for the motor in the MOTOR connector (use Tyco connector 640250-4
with Tyco terminal 3-770476-1).
PE:
grounding connection (use the 6.3 mm Faston Tab for connection).