TECHNICAL SHEET
Weights and sizes
Packing size (cm)
39x36x18,5
Gross weight (kg)
4,3
Product size (cm)
33x17/24x13
Working characteristics
Working power
6 W
Working frecuency
25 - 27 KHz
Preset working time
15 min
Electrical characteristics
Rated voltage
220V ~ 240V
Frecuency
50Hz/60Hz
Rated power
29 W
© 2013 Weelko
Visit our website at www.weelko.com for more information
WARNING
•
Never under any circumstances
attempt to open or inspect the internal
components or accessories of the
machine. If an inspection becomes
necessary, please contact your supplier
or a suitably competent technician.
•
Never use the unit in humid or poorly
ventilated environments, such as wet
rooms, bathrooms etc. to prevent damage
to the electrical components of your unit.
•
Never use the unit outdoors; exposure to
the elements can cause damage.
•
If the power cord was destroyed, please
ask a professional to service and replace
it to avoid hazards, or contact the dealer
for service.
•
It must be placed on a beauty trolley.
•
It must be used in an area where the
probe wire can be accessed (within 0.5
m).
•
Do not use it with 2m of accessible gas.
•
Power wire and machine frame shall be
used with 1,5m.
EC-DECLARATION OF
COMPLIANCE
This product meets the following
requirements:
1.
Conditions set out in the Low Voltage
Directive: 2006/95/EC
2.
Conditions set out in the
Electromagnetic Compatibility Directive:
2004/108/EC
RECYCLING
WELCOME!
Thank you very much for purchase.
Please read the instructions carefully
before operating the instrument. You can
also ask a professional for guidance to
make sure you are using the instrument
correctly. We will accept no responsibility
for any accidents that occur due to
incorrect operation.
The company reserves the right to amend
the details of the instruments with no prior
notice. If any mistakes are found in these
instructions, please feel free to send us an
e-mail informing us so that we can correct
them.
PACKAGE CONTENTS
•
These components are subject to
change without prior notice.
•
Appearance of product may differ from
the image.
No.
PRODUCT
REF.
QTY.
1
SKIN SCRUBBER PROBE
10018
1
2
SAFENER
-
1
3
BRACELET
10019
1
4
MAIN UNIT
-
1
5
FEEDER CABLE
-
1
FRONT PANEL/REAR PANEL
1.
Skin scrubber probe
2.
Bracelet
3.
Power line input
INSTRUCTIONS OF USE
1.
Connect the power supply via the rear
panel, indicated in the sketch as “POWER
LINE INPUT”.
2.
Connect the accessories properly to the
front/rear panel as indicated in the sketch.
3.
Turn on the “POWER” button.
GALVANIC USE
1.
Apply the correctly polarized product
over the skin area to be treated.
2.
Press the “P1 MODE” button to activate
the galvanic function.
3.
Select the polarity of the required
current by pressing the “LEAD” button to
switch between “+” (indicated by the “I”
LED) or “–” (indicated by the “O” LED).
Positive pole (I)
Negative pole (O)
Acid pH solutions
Alkaline pH solutions
5.
Adjust the “INTENSITY” to the desired
level.
6.
Use the probe over the skin.
ULTRASONIC PEELING USE
1.
Place the bracelet around the
customer’s wrist.
2.
Apply the appropriate conductive
product generously to the surface of the
skin.
3.
Press the “P2 MODE” button to activate
the peeling function.
4.
Select the desired kind of wave
(continuous, pulse or combined) by
pressing “STATE”.
5.
Adjust the “ENERGY” output to the
desired level.
6.
Use the probe over the skin.
COMBINED GALVANIC &
ULTRASONIC USE
1.
Place the bracelet around the
customer’s wrist.
2.
Apply conductive gel to the treatment
area.
3.
Press the “P1 MODE” and “P2 MODE”
buttons to activate the combined function.
4.
Select the desired kind of wave
(continuous, pulse or combined) by
pressing “STATE”.
5.
Adjust both the “INTENSITY” and
“ENERGY” to the desired output levels.
6.
Use the probe over the skin.
NOTES
•
A positive earth control system is in
place while the machine is operating.
This means that unless the machine can
find an earth return, the system will stop
the current output to the probe. However,
once the probe comes back into contact
with the customer (the earth circuit is
found), the system will restart the output
immediately. This is a safety feature and
should not be mistaken for a system fault.
•
The probe will not vibrate when used on
P1 program.
CAUTIONS
•
People suffering from the following
diseases are required not to use it: heart
diseases, infectious diseases, people
with metal implants and hypersensitive or
vascular skins.
•
Do not use the probe in one position on
the skin for too long, to avoiding the risk of
burning.
•
Always handle the probe with care as
it contains delicate components. Take
particular care of the probe blade as
any damage will cause scratching of the
skins surface during use. Always store the
probe safely when not in use.
FAQ
The probe suddenly stops emitting:
•
If the probe is separated from the skin, it
will stop emitting after 5 seconds. This is a
safety feature and should not be mistaken
for a system fault.
•
Touch the skin with the probe and it will
start emitting again after 5 seconds.
MAINTENANCE
•
Any oil on the probe must be removed
immediately.
•
After use, please clean the probe
and keep it. Store it in the probe-
protecting sleeve at all time.
•
Store the probe carefully to avoid
damaging it.
ACCESSORIES
REF.
DESCRIPTION
10018
SKIN SCRUBBER PROBE
SKIN EXFOLIATOR
EN
F-808
Instruction Manual
WE-2013-F808-1
Whenever any of our electrical
products or their presentation
packaging bear this symbol, it means
that these products should not be treated
as conventional household waste in
Europe. To ensure proper treatment of this
waste, dispose of it in accordance with
local laws or as required for the disposal
of electrical equipment. This initiative will
help preserve save natural resources and
improve standards of environmental
protection in regard to the treatment of
electrical waste.