background image

 

1.

 

Installation Steps

 

1)

Open the packing carton, connect and tighten the water pipe with shower head. (See as illustration 1)

 

2)

Assemble switch A as the installation diagram below. Put the metal cover on the square plastic strip. And then screw the 

inner hexagon screw on square plastic strip through the cover hole. Finally stopple the cover hole with red stopple.

 

 

 

 

   

 

 

 

 

Illustration 1 

 

 

 

          

 

 

         

 

 

                             

 

Installation Diagram of Switch A 

 

 

 

 

 

Allen key 

Stopple 

Inner hexagon screw 

Square plastic strip 

Metal upper cover 

Switch for cool and hot water exchanging 

Cover hole 

Switch A 

 

Shower head 

 

 

 

Water inflowing pipe 

 

Summary of Contents for 4122B

Page 1: ...User Manual for 4122B 4122C Foot SPA Chair...

Page 2: ...t Picture QTY 01 Shower Head 1 09 Allen Key 1 02 Seal Ring 2 10 Hand Controller 1 03 Seal Ring 2 11 5 X20 Tapping Screw 3 04 Drainage Pipe 1 12 Power Cord 1 05 M10X35 Inner Hexagon Screw 4 06 Gasket 4...

Page 3: ...cover on the square plastic strip And then screw the inner hexagon screw on square plastic strip through the cover hole Finally stopple the cover hole with red stopple Illustration 1 Installation Dia...

Page 4: ...e and inflow pipe as following Left is for cool water right is for hot water a See illustration 2 for the standard configuration Illustration 2 b Put the end of drainage pipe into the floor drain outl...

Page 5: ...ew the 4PCS M10 inner hexagon screws together with the gaskets STEP 1 Put the base of massage chair on the foot SPA STEP 2 There s a hole at the backside of base You can screw the screws gaskets and s...

Page 6: ...Allen Key Spring Gasket M10X35 Inner Hexagon Screw Gasket STEP 3 6 Assemble the backrest of foot SPA chair as illustrations below...

Page 7: ...7 Assemble the upholstery for the backrest as illustration below 8 Put the cushion on the seat while connecting the air pipe Plug the motors on the control box corresponding to the number marked...

Page 8: ...ft for hot water right for cool water Foot support with PU Button of SPA massaging and LED light Water overflow opening Multicolor LED light Pipeless pump with underwater and whirling massage Button o...

Page 9: ...ssaging and lighting 4 Button of shower jetting Adjust water jet from the shower by push it up and down Besides shower hose can be stretched out and drew back so as to make more convenience for client...

Page 10: ...rt of Body Adjustment for the Height of Seat Adjustment for the Angle of Backrest Adjustment for the Angle of Seat Adjustment for the Massaging area It lights up when the area is doing air massage It...

Page 11: ...Music Player Chair Adjustment Button for adjust the angle of backrest Upper for decrease the angle bottom for increase the angle Keep on pressing button to continuously adjust the angle Press AUTO but...

Page 12: ...ing the USB or SD card Previous song Next song Voice decreasing Voice increasing 3 Warning Note Pay attention on following items to prevent from burn electric shock fire and other danger 1 Unplug the...

Page 13: ...ll 3 It would be better to wear light clothes for treatment But do not without clothing please Do not have treatment when you wear something hard on your head a Do not massage for over 5min at the fir...

Page 14: ...ight be defective if you repeatedly switch on off in a short time 6 If the performance of chair is defective or after you repair or replace a new circuit board you can reinitialize the electric circui...

Page 15: ...he nut can solve the problem You may even add some glass cement on the joint if necessary d Massage Chair might sounds loudly after using for a long time Add some grease on the four wheeled massage ha...

Reviews:

Related manuals for 4122B