![Weelko 4122B User Manual Download Page 15](http://html1.mh-extra.com/html/weelko/4122b/4122b_user-manual_950396015.webp)
12.
Signs of Error
:
a)
There is “E1/ E2/ E3” showed on the timer , and it keeps flashing. Meanwhile, all buttons don’t work.
b)
There is “88” showed on the timer , and it keeps flashing.
Code of Error
E1
E2
E3
88
Issues
Motors for movement
are defective
Motor controlled for
massage is defective
Four-wheeled massage
hand is defective
Hand controller doesn’t
connect well with
electric circuit board
6. Maintenance
a)
Clean basin with cloth after SPA, so as to extend the lifetime of basin.
b)
If there is dirt or slight scratches on the basin after using for a long time, you could sand it with a #2000 sandpaper
and water.
c)
It is unavoidable that basin will be ageing after using for a long time. Replace corresponding parts if necessary.
If you found water dropping or leaking, replacing a new sealing gasket and tightening the nut can solve the problem.
You may even add some glass cement on the joint if necessary.
d)
Massage Chair might sounds loudly after using for a long time. Add some grease on the four-wheeled massage hand
can solve this problem.
e)
Clean with soft towel and some alcohol if there is dirt on the upholstery.
7. Technical Parameter
Power supply AC110V
、
220V
、
240V as option
Input frequency 50-60Hz
Distance between upper and bottom wheels of massage hand approx 0-600mm
Movement distance of four-wheeled approx 450mm
Distance between left and right wheels of massage hand approx 30-200mm
Speed for the movement of massage hand about 14s per round
Pressure of Air Massage 30~40kPa
Adjustable Angle of Backrest approx 105-125
°
Distance Between forward and backward approx 0-100mm
Distance Between Up and down approx 0-100mm (only to 4122C)
Time setting ≤20min
Size of Foot SPA Chair approx 1650×810×1500mm
(Length × Width × Height, Chair isn’t slant)
Packing Size: Massage Chair: 1180×720×600(mm)
Foot SPA base 1470×850×510(mm)