background image

 

8

MAINTENANCE 

 

Every 6 month the oil in the seal unit and the complete pump must be inspected . 
The following figures shows the pump assembly  (except for figures 7 and 8 which are showing specials  
disassembly tools) . For disassembly proceed in reverse order .   
 

GENERAL 

When dismounting the pump replace systematically all the O-ring , wear plate , diffusor centre and the damaged parts . 
Replace the oil into the seal unit ( 7 l. SHELL Tellus Oil 32) . 
Slightly oil the O-rings , the assembly surfaces and the threads . Tighten firmly all the nuts . The  rotor shaft nut and the 
impeller nut have to be tight to 400Nm  . These nuts and the pump stud bolts have to be glued with Loctite N° 242  . 
 

PUMP UPPER PARTS 

- Put the top bracket of the pump on a holder placed on the ground 

Fig 2

 . Note that the part is equipped with two lifting 

eyes in order to facilitate the pump manipulation . 
- Screw in place 6 stud bolts P/N 69674 and set 2 O-rings W65142 in place into their grooves 

Fig 3

 .  

Note : When delivered as spare part the top bracket cpl. P/N 492022 includes : Stud bolts W69674 (x6) ,  
stud bolts W69652 ( x4) , stud bolts P/N W69654 (x4) , stud bolts P/N W494079 (x2) and stud bolts W69658 (x4) . 
Lubricate with high temperature bearing grease the emplacement for the bearing . 
- Put in place the inner casing cpl . (including the stator) on the top bracket  

Fig 3 

and

 fig 4

 . 

Summary of Contents for RL 8010

Page 1: ...INSTRUCTIONS SPAREPARTS CATALOGUE R RL L 8 80 01 10 0 RL8010 IS 10594 ENG GSNL...

Page 2: ...e of the machine is restricted to the applications specified in the product literature Always change damaged parts immediately Change wear parts in due time SAFETY EQUIPMENT WARNING The admissible sou...

Page 3: ...tain situations Keep away from all hot or spark generating objects do not smoke when handling fuel Wait until the machine has cooled before filling the tank Avoid spilling petrol or diesel on the grou...

Page 4: ...Hi Chrome iron and all other components are rubber lined The impeller clearance is easily adjustable to compensate for wear TECHNICAL DATA RL8010 Pump Discharge mm in 255 10 Suitable for media with p...

Page 5: ...5 Hydraulic characteristics 50Hz 60Hz Dimensions Dimensions in mm Dimensions in inch 600 23 6 1435 56 5 medium head...

Page 6: ...explosive inflammable environment or used to pump inflammable liquids Route the cables so that connectors do not lie in the water Consider the risk of electrical accident Never lift the pump by its p...

Page 7: ...o normal working temperature the motor protection switches on the contactor and the pump starts again TROUBLE SHOOTING Fault location Cause Action Pump will not start 1 Fuses blown 2 Broken cable 3 Po...

Page 8: ...mpeller nut have to be tight to 400Nm These nuts and the pump stud bolts have to be glued with Loctite N 242 PUMP UPPER PARTS Put the top bracket of the pump on a holder placed on the ground Fig 2 Not...

Page 9: ...the casing cpl Fig 6 Set the bearing housing complete See page 19 on the rotor end Fig 7 and secure it with retaining ring P N W50553 Note dismantling of bearing housing cpl Fig 8 Slide the complete r...

Page 10: ...ered with O rings assembled Put in place the seal unit cpl on the inner casing on the stud bolts according to Fig 9 Fig 9 WEAR PLATE Set in place the wear plate P N W492017 using a mallet The wear pla...

Page 11: ...The gap between the impeller and the wear plate must be as small as possible It is settled with Trimming spacers P N W494044 On a new pump there is 5 washers in order to get the right gap When the pum...

Page 12: ...casing the bolts P N W494054 using Loctite N 242 Arrange to have the outer casing holes in front of the seal unit plugs Then set in place the outer casing on the top bracket Fig 15 Note Fig 14 disasse...

Page 13: ...13 DIFFUSOR Set in place the diffusor P N W491006 on the pump stud bolts and secure it with nuts P N W84215 x8 Fig16 Note Disassembly method Fig 17 and 18 Fig18...

Page 14: ...tre and the impeller must be as small as possible Adjust this gap tanks to nuts P N W84215 Avoid to get any contact between the impeller and the diffusor centre Fig 20 As soon as the setting is made p...

Page 15: ...TRAINER Put in place the strainer P N W491007 using nuts P N W54215 x4 Then return the pump Fig 22 and screw in place lifting eyes P N W494085 and the pump discharge See discharges available page 6 Fi...