6
DISCHARGES AVAILABLE
10" Hose standard P/N W494102
10" BSP - thread P/N W494103
10" NPT - thread P/N W494104
10" Alvenius P/N W494105
Note :the discharges have to be ordered separately
.
PUMPS PART NUMBERS
Power supply
Part Number (1)
380/660V-3-50Hz RL8014B37A6
440V-3-60Hz RL8015B37A2
(1) The letter B means. basic construction, but the following main options are also available , according to the pump
type :
H : Canada Standard Association certified.
Z : Zinc anodes.
Here is the combinations for the most common pumps . In case of special applications please contact us .
INTALLATION
The pump must not be used in an explosive / inflammable environment or used to pump inflammable
liquids !
- Route the cables so that connectors do not lie in the water. Consider the risk of electrical accident.
Never lift the pump by its power cable !
- Connect a discharge hose of approved pressure class.
- The discharge hose may be thrown off when the pump starts.
- No one must be allowed in the water, e.g. swimming pools, when the pump is running.
- Check that the pump is standing steady, or suspend it from its lifting ring.
- Check the direction of rotation, pointed by the starting kick arrow printed in the outer casing (anti-clockwise)
The pump will start instantaneously when it is connected to the power supply.
The pump may kick violently when it starts.
In case of wrong direction of rotation two phases should be inverted from the supply.