3.5
LOCKING PROCEDURE
The locks are enabled only in MIG/MAG welding mode.
The procedure inhibits unit adjustments, allowing the user to modify only certain settings depending on the selected lock status.
The procedure is used to prevent accidental alteration of the unit settings and welding settings by the operator.
Enabling
If no locking status is selected (LOC = oFF) and if you wish to set up a limitation on use of the power source, display the LOC function in the
SETUP menu.
Open the Setup menu.
The acronym relative to the setting to be edited appears on the following displays: D1
The value relative to the selected setting appears on the following displays: D2
E1
Use the encoder to select the following setting: LoC
E2
Use the encoder to select the required lock status.
Depending on the selected Lock, certain functions will remain enabled.
E1
Use the encoder to select the following setting: ESC
S2
Press any button to save the setting and quit the menu.
Tab. 3 - Functions not disabled by Locks
LOCK
STATUS
USER INTERFACE
RC03
RC04
RC05
RC06
OFF
All adjustments enabled.
All adjustments enabled. All adjustments enabled. All adjustments enabled. All adjustments enabled.
1
Selection of torch trigger procedure (button S5)
Display of main welding parameters (button S2)
Arc correction (encoder E2)
Wire insertion (button S1)
Gas test (button S3)
Arc correction
(Potentiometer Pot2)
Arc correction (UP/DOWN
lever 2)
2
Selection of torch trigger procedure (button S5)
Display of main welding parameters (button S2)
Arc correction (encoder E2)
Synergy (encoder E1)
Wire insertion (button S1)
Gas test (button S3)
All adjustments enabled. All adjustments enabled. All adjustments enabled. All adjustments enabled.
3 (*1)
Selection of torch trigger procedure (button S5)
Display of main welding parameters (button S2)
JOB selection (encoder E2)
Wire insertion (button S1)
Gas test (button S3)
Scroll JOBS (UP/DOWN
lever 1)
Scroll JOBS (UP/DOWN
lever 1)
Disabling
If a lock status is selected, you can only edit parameters permitted by the currently active lock status.
Open the Setup menu.
The acronym relative to the setting to be edited appears on the following displays: D1
The value relative to the selected setting appears on the following displays: D2
E1
Use the encoder to select the following setting: LoC
E2
Use the encoder to select the following setting: oFF
E1
Use the encoder to select the following setting: ESC
S2
Press any button to save the setting and quit the menu.
3.6
GAS FLOW ADJUSTMENT
When the unit is powered on the solenoid valve opens for 1 second.
This serves to fill the gas circuit.
S3
Open the gas solenoid valve by pressing and releasing the button.
Adjust the pressure of gas flowing from the torch by means of the flow meter connected to the gas cylinder.
S3
Close the gas solenoid valve by pressing and releasing the button.
The solenoid valve closes automatically after 30 seconds.