English
5
Model Number
Flow Range (lpm)
Pressure Range (bar)
Inlet/Outlet Ports
DHT401-B-6
10 - 400
0 - 420
1” BSPP
DHT801-S-7-L
20 - 800
0 - 480
1-7/8” -12UN #24 SAE ORB
DHT801-F-3-L
20 - 800
0 - 210*
1-1/2” SAE Code 61 4-Bolt Flange
Specification
EU (lpm/Centigrade)
US (gpm/Fahrenheit)
Flow Accuracy: ± 1% of full scale.
Pressure Accuracy: ± 1.6 % of full scale.
Temperature Accuracy: ± 1°C, 2°F.
* per J518 SAE Code 61 standard
Model Number
Flow Range (gpm) Pressure Range (psi)
Inlet/Outlet Ports
DHT401-S-6
2.5 - 100
6000
1-5/16” -12UN #16 SAE ORB
DHT801-S-7
5 - 210
7000
1-7/8” -12UN #24 SAE ORB
DHT801-F-3
5 - 210
3000*
1-1/2” SAE Code 61 4-Bolt Flange
DHT 1 Series Digital Hydraulic Tester
Digital display
Pressure gauge
Battery cover
On/Off switch