Basic operation

Flow measurement

The tester measures flow using an axial turbine mounted in the aluminium base block. The 

oil flow rotates the turbine and its speed is proportional to the oil velocity. The revolutions of 

the turbine are measured by means of a magnetic sensing head which feeds a pulse every 

time a turbine blade goes by to an electronic circuit. The electronic circuit has a built-in micro 

processor; the signal is amplified and linearised to maximise accuracy. The readout is calibrated 

in lpm or gpm, units are selectable on some models.

Pressure measurement

Where fitted, the pressure gauge has a spiral Bourdon tube and the gauge case is filled with 

glycerine to ensure good dampening of pulsating pressures. The gauge is connected to the base 

block by a fine bore capillary tube. The DHM series meters have a pressure transducer fitted 

directly to the base block which improves fast transient capture. All testers are bi-directional 

and incorporate a shuttle valve which directs the highest pressure (from inlet or outlet) to the 

measuring point. A gauge port is provided on the back of the base block for the addition of a 

low pressure gauge kit.

Temperature

The Thermistor temperature transducer is in contact with the oil flow and readout is on the meter 

scale calibrated 32 - 250°F or 0 - 120°C.

Bi-Directional Loading Valve

The reverse flow valve gives positive shut-off and pressure control in both directions of flow. 

The loading valve has two easily replaceable safety discs located in the valve assembly which 

internally protect the tester and machine in both flow directions.

Installation guidance

l

  All hydraulic connections should be made by suitably qualified personnel. 

l

 

Avoid sharp bends because high pressure hoses will deflect and straighten under pressure.

l

 

A  preliminary  check  of  the  hydraulic  system’s  oil  supply,  pump  rotation,  filters,  oil  lines, 

cylinder rods as well as looking for external leaks should be made prior to installing the 

Hydraulic Tester.

l

 

Although the Bi-Directional tester can be used in both flow directions, the preferred direction 

is indicated by the larger arrow on the panel. When the tester is used for reverse flow 

tests, slightly lower accuracies may be obtained depending on the oil viscosity, density and 

compressibility.

l

 

The tester should be connected to the hydraulic circuit by means of flexible hoses 1 - 2 

metres long. 

l

 

The use of quick-disconnect couplings can save time. Make sure the hoses are long enough 

so that the tester can be used safely on the machine. 

l

 

The hoses and fittings at the inlet to the tester must be of adequate size for the flow being 

tested. Elbows, rotary couplings etc., at the inlet and outlet ports of the tester should be 

avoided to ensure accurate readings.

l

 

The use of the flexible hoses will help to isolate the test unit from vibration which often exists.

l

 

The internal burst discs are to protect the tester not the hydraulic installation. Always ensure 

the appropriate relief devices are fitted to protect the installation.

Summary of Contents for DHT401

Page 1: ...raulic Testers User Manual Bedienungsanleitung f r tragbare Hydraulik Testger te der Reihen 1 2 und 4 Manuel d utilisation des Testeurs Hydrauliques portables des s ries 1 2 4 Manual de usuario de los...

Page 2: ...and receiver l Connect the equipment into an outlet on a circuit different from that to which the receiver is connected l Consult the dealer or an experienced radio TV technician for help Canada This...

Page 3: ...Series Digital Hydraulic Multimeter There are different sizes and porting options to cover a wide range of flows This manual covers all testers Before first operating the equipment read the whole of t...

Page 4: ...trol in both directions of flow The loading valve has two easily replaceable safety discs located in the valve assembly which internally protect the tester and machine in both flow directions Installa...

Page 5: ...ne and adjust the loading valve as needed 9 When the test is completed fully open loading valve Notes When low pressure testing is required connect the optional low pressure gauge with automatic cut o...

Page 6: ...mm 10 kg DHT602 802 8 86 inches 9 65 inches 8 86 inches 22 lbs DHM804 Fluid viscosity The performance of the tester can be affected by the viscosity of the fluid measured Our testers are calibrated a...

Page 7: ...gpm Fahrenheit Flow Accuracy 1 of full scale Pressure Accuracy 1 6 of full scale Temperature Accuracy 1 C 2 F per J518 SAE Code 61 standard Model Number Flow Range gpm Pressure Range psi Inlet Outlet...

Page 8: ...nfra red phototachometer l Selector switch Turn the switch to select the required function l OFF RESET Switches the tester off and resets the unit after automatic power shut off l B TEST Checks the co...

Page 9: ...peed Needs optional infra red phototachometer using one or more retro reflective marks Range See Table Accuracy 2 of full scale per J518 SAE Code 61 standard Model Flow Flow Scales Pressure Speed Inle...

Page 10: ...n socket for the optional infra red phototachometer l External flow Connection socket for optional second LT series flow meter to measure a second flow and temperature l Selector switch Turn the switc...

Page 11: ...Mode EXT INT and TACH External Flow EXT 1 Turn selector switch to Ext Flow 2 Press C F button and hold down Then press ON i e two buttons are pressed at the same time 3 On the left side of the display...

Page 12: ...Q Pressing this button will change the bottom line of the display from temperature to power This button is also used to start the efficiency display on screen 3 l Clear peak Press to clear the peak pr...

Page 13: ...from the flow and pressure the hydraulic power is displayed in either HP or KW The engineering units for power are linked to the pressure units and can be changed using the pressure units button on th...

Page 14: ...igital Screen 2 Analogue Screen 3 P Q Bar graph scaling EU US DHM404 DHM804 DHM404 DHM804 Flow LPM 0 400 0 800 GPM 0 100 0 210 Pressure BAR 0 600 0 600 PSI 0 8700 0 8700 Peak BAR 0 600 0 600 PSI 0 870...

Page 15: ...ure display between power and temperature When the meter is turned ON the contrast buttons can be used to adjust the display to suite the ambient light conditions Settings are saved Pressing the clear...

Page 16: ...ted by the soft menu keys designated on the bottom line Clear peaks button becomes the scroll UP key Pressure unit s button becomes the scroll DWN key PQ HP button becomes the DEL key The soft menu ac...

Page 17: ...machine For 2 series testers only Infrared photo tachometer comprises infrared photo tach head six metre connecting cable and reflective tape The BA20 magnetic base with flexible arm is also available...

Page 18: ...i que les autres obligations et responsabilit s Aucun agent revendeur ou distributeur en aucun cas n a le pouvoir ou l autorit de modifier les termes de cette garantie F nf Jahre begrenzte Garantie de...

Page 19: ...previo aviso For Sales Service contact Auskunft Beratung Contact Service commercial maintenance Para m s informaci n sobre ventas y servicios contactar con Distributor Vertriebspartner Distributeur D...

Reviews: