6
Test connections
All connections and joints must be thoroughly tested for
leaks in accordance with local codes and all listed
procedures in the latest edition of ANSI Z223.1/NFPA 54.
DANGER
Do not use an open flame to check for gas
leaks. Be sure there are no sparks or open
flames in the area while you check for gas
leaks. This will result in a fire or explosion
which can cause serious bodily injury or
death, and damage to property.
If you have any questions, contact the Vieluxe
®
Customer
Service Center at 1-866-VIELUXE
sm
.
CONNECT GAS SUPPLY
A 48" inch corrugated gas line is supplied with the grill.
This line needs to pass through the gas inlet opening to
the main gas supply.
1) Connect the corregated gas line to the manifold
located on the right hand side of grill under the
control panel.
Note: Leave an access in the “island” structure for gas
supply and regulator service not inside the grill structure.
Vieluxe
®
has a gas line and regulator access door
(#36311) available from your dealer or call
Vieluxe
®
Customer Service at 1-888-VIELUXE.
The corrugated line passes through the "Island Structure"
cavity to the regulator connection inside the Vieluxe
®
Built-In tank cabinet (#36399) or the hose and regulator
connection from kit #36300. (Shown below)
Typical tank cabinet
or tank enclosure location