20
WWW.WEBER.COM
®
Table
10-1
Maximum Capacity of Pipe in Cubic Feet of Gas per Hour for Gas Pressures of 0.5 psi or Less and a Pressure Drop of 0.3 Inch
Water Column. (Based on a 0.60 Specifi c Gravity Gas)
Nominal
Iron Pipe
Size
(Inches)
Internal
Diameter
(Inches)
Length of Pipe (Feet)
10
20
30
40
50
60
70
80
90
100
125
150
175
200
1/4
.364
32
22
18
15
14
12
11
11
10
9
8
8
7
6
3/8
.493
72
49
40
34
30
27
25
23
22
21
18
17
15
14
1/2
.622
132
92
73
63
56
50
46
43
40
38
34
31
28
26
3/4
.824
278
190
152
130
115
105
96
90
84
79
72
64
59
55
1
1.049
520
350
285
245
215
195
180
170
160
150
130
120
110
100
1 1/4
1.380
1050
730
590
500
440
400
370
350
320
305
275
250
225
210
1/12
1.160
1600
1100
890
760
670
610
560
530
490
460
410
380
350
320
2
2.067
3050
2100
1650
1450
1270
1150
1050
990
930
870
780
710
650
610
2 1/2
2.469
4800
3300
2700
2300
2000
1850
1700
1600
1500
1400
1250
1130
1050
980
3
3.068
8500
5900
4700
4100
3600
3250
3000
2800
2600
2500
2200
2000
1850
1700
4
4.026
17500
12000
9700
8300
7400
6800
6200
5800
5400
5100
4500
4100
3800
3500
© 1997 National Fire Protection Association, Inc. and International Approval Services - U.S., Inc. All Rights Reserved.
TYPICAL BULK PROPANE GAS SUPPLY INSTALLATION
We recommend that this installation be done by a LICENSED professional.
GENERAL SPECIFICATIONS FOR PIPING
Note - Contact your local municipality for building codes regulating outdoor gas grill
installations. In absence of Local Codes, you must conform to the latest edition of the
National Fuel Gas Code ANSI Z223.1/NFPA 54, Natural Gas and Propane Installation
Code, CSA B149.1, or Propane Storage and Handling Code, B149.2, or the Standard for
Recreational Vehicles, ANSI A 119.2/NFPA 1192, and CSA Z240 RV Series, Recreational
Vehicle Code, as applicable.
•
This grill is designed to operate at 11 inches of water column pressure. An LP in
line regulator may be necessary for this pressure.
CAUTION: If young children are in the area, a locking valve
should be considered.
•
Pipe compound should be used which is resistant to the action of liquid propane
gas when gas connections are made.
•
The gas connections must be fi rmly attached to rigid, permanent construction.
Note: The information provided in this manual is general for typical installations. We
cannot cover all possible installation ideas. We recommend, prior to installation, that
you contact your municipality for local building codes and your local fi re department for
installation verifi cation.
If you have any questions, contact Customer Service at 1-800-446-1071.
BUILT-IN GAS LINE LOCATIONS
Note: Leave an access in the “island” structure for gas supply and regulator service that
is not inside the grill structure. Weber
®
has a gas line and regulator access door (part #
36311) available from your dealer or call Customer Service at 1-800-446-1071.
Note: Area should be kept clear of sharp, jagged, or extremely abrasive surfaces to avoid
possible damage to gas supply lines. Exercise caution when pulling gas lines through
built-in structure.
1
1
2
2
3
3
a
b
c
DIMENSIONS
BUILT-IN GAS LINE LOCATIONS
SILVER
GOLD
TOLERANCES
1
3 3/4˝
(95.3 mm)
3 3/4˝
(95.3 mm)
+1/8˝(3.8mm)
- 1/8˝(3.8mm)
2
6 1/4˝
(158.8 mm)
6 1/4˝
(158.8 mm)
+1/8˝(3.8mm)
- 1/8˝(3.8mm)
3
2 1/2˝
(63.5 mm)
2 1/2˝
(63.5 mm)
+1/8˝(3.8mm)
- 1/8˝(3.8mm)
a
Plan View Left
b
Side View
c
Gas Inlet
GAS SUPPLY
Summary of Contents for Summit S-440
Page 8: ...8 WWW WEBER COM 5 6 Back ASSEMBLY...
Page 9: ...9 WWW WEBER COM 9 7 ASSEMBLY...
Page 12: ...12 WWW WEBER COM F S440 11 1 3 2 12 ASSEMBLY...
Page 13: ...13 WWW WEBER COM 13 S640 S440 13 14 1 2 S640 S440 ASSEMBLY...
Page 14: ...14 WWW WEBER COM S640 S440 a b c 15 Match Holder ASSEMBLY...
Page 15: ...15 WWW WEBER COM 15 S640 S440 16 17 1 4 6 35 mm Drill Bit ASSEMBLY...
Page 16: ...16 WWW WEBER COM S640 S440 18 19 20 S440 S640 S640 S440 ASSEMBLY...
Page 17: ...17 WWW WEBER COM 17 ASSEMBLY 21 S640 S440...
Page 18: ...18 WWW WEBER COM 1 2 3 22 S 440 S 640 ASSEMBLY...